background image

Installation Instructions

PLUMBING INFORMATION

WATER SUPPLY REQUIREMENTS

‡ +27$1'&2/':$7(5)$8&(76²0XVWEHZLWKLQµRI

the appliance water inlet hose connections. The faucets 

PXVW EH µ JDUGHQ KRVHW\SH VR LQOHW KRVHV FDQ EH

connected.

‡ :$7(535(6685(²0XVWEHEHWZHHQDQGSRXQGV

per square inch with a maximum unbalance pressure, 

KRWYVFROGÀRZLQJRISRXQGVSHUVTXDUHLQFK

‡ :$7(5 7(03(5$785( ² :DWHU KHDWHU VKRXOG EH VHW WR

GHOLYHU ƒ) ƒ& LQ WKH ZDVKHU ZKHQ +27 ZDVK LV

selected.

‡ 6+872)) 9$/9(6 ² %RWK KRW DQG FROG ZDWHU VKXWRȺ

YDOYHVIDXFHWVVKRXOGEHVXSSOLHG

‡ /2&$7,21²'RQRWLQVWDOODSSOLDQFHLQDQDUHDZKHUHWKH

WHPSHUDWXUHZLOOIDOOEHORZIUHH]LQJ,IDSSOLDQFHLVVWRUHG
RUWUDQVSRUWHGLQIUHH]LQJWHPSHUDWXUHVEHVXUHDOOZDWHU
IURPWKH¿OODQGGUDLQV\VWHPVKDVEHHQUHPRYHG

DRAIN REQUIREMENTS

‡ '5$,1 5$7( ² 7KH GUDLQ RU VWDQGSLSH PXVW EH FDSDEOH

RI DFFHSWLQJ D GLVFKDUJH DW WKH UDWH RI  JDOORQV SHU

minute.

‡ '5$,1+(,*+7²7KHGUDLQKHLJKWPXVWEHµPLQLPXP

DQGµPD[LPXP

‡ 67$1'3,3( ',$0(7(5 ² 7KH VWDQGSLSH GLDPHWHU PXVW

EH µ PLQLPXP 7KHUH 0867 EH DQ DLU JDS DURXQG
WKHGUDLQKRVHLQWKHVWDQGSLSH$VQXJ¿WFDQFDXVHD

siphoning action.

‡ 6,3+21 %5($. ² )RU D GUDLQ IDFLOLW\ OHVV WKDQ µ KLJK

the hose, coupling and clamps provided in the machine 
must be used and, in addition, a siphon break MUST be 
installed on the back of the machine. Obtain and use a 
siphon break kit and follow the instructions in the kit.

7

CONNECTING TO PLUMBING FACILITIES

If not installed, install rubber washer in one end of hot water hose. 

Thread hot water hose onto connection labeled 

H

 at top rear 

RDQGWLJKWHQSOXVDQDGGLWLRQDOWXUQZLWKSOLHUV

If not installed, install rubber washer in one end of cold water 

hose. Thread cold water hose onto connection labeled 

C

 at top 

UHDURDQGWLJKWHQSOXVDQDGGLWLRQDOWXUQZLWK

pliers.

0RYHDSSOLDQFHDVFORVHWR¿QDOORFDWLRQDVSRVVLEOHOHDYLQJURRP

for you to make water, drain, electrical and vent connections to 

your home.

8

C

H

HOT

HOT

HOT

HOT

COLD

COLD

COLD

COLD

NOTE:

 If longer drain hose 

is required, order drain hose 

extension kit , part number 

:+;&RQQHFWDGGLWLRQDO
GUDLQ KRVH FRQWDLQHG LQ NLW WR

original hose with hose clamp 

FRQWDLQHGLQNLW

Insert free end of drain hose into 

drain opening of your home up 

WR GUDLQ KRVH VWRSSHU GR QRW

remove hose stopper it prevents 

VLSKRQLQJ ,I ZDWHU YDOYHV DQG

drain are built into wall, fasten 

drain hose to one of water 

hoses with cable tie provided 

ULEEHG VLGH RQ LQVLGH ,I \RXU

drain is a standpipe, fasten drain 

hose to standpipe with cable tie 

provided.

Содержание GUD27ESMMW

Страница 1: ...d carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer H VXUH WR OHDYH WKHVH instructions with the customer Note...

Страница 2: ...ing prong from the power cord Follow national electrical codes and ordinances This appliance must be supplied with the voltage DQG IUHTXHQF LQGLFDWHG RQ WKH UDWLQJ SODWH ORFDWHG DW WKH WRS RI WKH GU H...

Страница 3: ...can be adjusted 375 74 5 Vent Drain outlet UHDU 4 2 8 2 2 2 75 Gas Inlet 5HDU YLHZ RI DSSOLDQFH Water Inlets UHDU Dimension represents door closed including handle and knobs NOTE With feet set at mid...

Страница 4: ...ed In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance of electric current This appliance is HTXLSSHG ZLWK D FRUG KDYLQJ D...

Страница 5: ...H RQ QHZ FRQVWUXFWLRQ 127 IRU XVH RQ UHFUHDWLRQDO YHKLFOHV 127 IRU XVH LQ DUHDV ZKHUH ORFDO FRGHV SURKLELW JURXQGLQJ through the neutral conduction 7XUQ R WKH FLUFXLW EUHDNHU V DPS RU UHPRYH WKH dryer...

Страница 6: ...T INFORMATION WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE 8VLQJ H KDXVW ORQJHU WKDQ VS...

Страница 7: ...the more the unit will vibrate STANDARD REAR EXHAUST 9HQWHG DERYH RRU OHYHO 2 5 200 1 5 200 1 21 85 7 21 72 0 1 0 867 2 NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING WARNING TO REDUCE THE RISK...

Страница 8: ...s UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the GU HU WR WKH KRXVH YHQW XVLQJ D H LEOH PHWDO IRLO W SH GXFW 8 OLVWHG H LEOH PHWDO IRLO...

Страница 9: ...WARNING Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct 4 UL approved rigid metal DUCT TAPE 27 MODELS ONLY DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET WA...

Страница 10: ...coupling and clamps provided in the machine must be used and in addition a siphon break MUST be installed on the back of the machine Obtain and use a siphon break kit and follow the instructions in th...

Страница 11: ...ATION If your appliance is approved for installation in an alcove or closet it will be stated on a label on the appliance back 72 35 9 17 5 028176 2 17 1 02 6785 520 808 7 1 1 72 0 17 1 5 1 1 7 6 0 1...

Страница 12: ...IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INSTALLATION For replacement parts and other information refer to Owner s Manual for servicing phone numbers 5 67 5 285 1 33 1 72 5 9 1 03257 17 352 8...

Страница 13: ...Rondellesen Caoutchouc Rondelles en caoutchouc OHV MRLQWV SHXYHQW HQWUH GDQV OHV WX DX D HDX 2 tuyaux de la laveuse 1 collier en plastique AVANT DE COMMENCER Lisez les instructions compl tement et ave...

Страница 14: ...V HVW VX VDQWH HW DSSDUHLO ne devrait pas tre install sur untapis ou expos au climat PLOMBERIE 35 66 21 8 OOH GRLW rWUH GH SVL PLQLPXP HW 120 psi maximum 7 03 5 785 8 OH FKDX H HDX GH YRWUH PDLVRQ GRL...

Страница 15: ...ons en pieds correspondant 375 8 2 17 9 32 7 27 325 19 1 DIMENSIONES NOMINALES DU PRODUIT 27 75 5 52 9 3 9 26 8 36 5 26 7 47 Dimensions lorsque les portes sont ferm es incluant les poign es et les bou...

Страница 16: ...ence GH QRUPHV ORFDOHV FRQIRUPpPHQW 8 1250 6 75 48 6 1 7 21 6 16 1 3 12 RX D 1RUPH pOHFWULTXH FDQDGLHQQH 6 CONDITIONS ELECTRIQUES Cet appareil doit tre branch une prise lectrique LQGLYLGXHOOH SURWpJpH...

Страница 17: ...ilis e dans les nouvelles constructions Ne peut pas tre utilis e dans les v hicules r cr atifs Ne peut pas tre utilis e dans les r gions o les codes locaux LQWHUGLVHQW OD PLVH j OD WHUUH SDU OH ELDLV...

Страница 18: ...e ignor Deux coudes de 45 devraient tre trait s comme un coude de 90 Chaque coude de plus de 45 devrait tre trait comme un coude de 90 SCELLAGE DES JOINTS 7RXV OHV MRLQWV GHYUDLHQW rWUH VHUUpV SRXU pY...

Страница 19: ...ARRIERE STANDARD Ventil au dessous du niveau du sol 5 METTRE A NIVEAU ET STABILISER VOTRE APPAREIL Mettre niveau et stabiliser votre appareil pSODFH SUXGHPPHQW O DSSDUHLO YHUV VD SRVLWLRQ QDOH DODQFH...

Страница 20: ...les il peut tre n cessaire de EUDQFKHU OD VpFKHXVH j O DpUDWLRQ GH OD PDLVRQ XWLOLVDQW XQ WX DX H LEOH HQ PpWDO DOXPLQLXP 8Q WX DX 8 H LEOH HQ PpWDO VHPL ULJLGH QH SHXW SDVrWUH XWLOLVp 7 FHFL R XQ dia...

Страница 21: ...anchez le coude interne AVERTISSEMENT Assurez vous de ne SDV WLUHU RX HQGRPPDJHU OHV OV pOHFWULTXHV j O LQWpULHXU de la s cheuse lorsque vous ins rez le tuyau UNIQUEMENT POUR MODELES DE 27 PO ECHAPPEM...

Страница 22: ...areil doivent tre utilis s et GH SOXV XQ EULVH VLSKRQ 2 7 rWUH LQVWDOOp DX GRV GH OD PDFKLQH 2EWHQLU HW XWLOLVHU XQ NLW EULVH VLSKRQ HW VXLYH OHV LQVWUXFWLRQV GX NLW 7 BRANCHER LA PLOMBERIE QVWDOOH VL...

Страница 23: ...YRWUH DSSDUHLO HVW DXWRULVp SRXU XQH LQVWDOODWLRQ GDQVXQ emplacement ou un meuble cela sera indiqu sur laplaque au dos de l appareil 3285 9 7 5 81 5 1 120 5 3 8 6 7 80 7 86 6 3 5 808 7 21 7 3285 0 17...

Страница 24: ...T APRES REPARATION ET D INSTALLATION Pour les pi ces de rechange et autres informations veuillez reporter au Manuel de l Utilisateur pour les num ros de t l phone du service apr s vente 15 675 9275 12...

Отзывы: