Страница 1: ...S rie T0 CODES PANNES et AUTOTEST...

Страница 2: ...eans 14 Daily 60 15 Rapid 15 16 OFF Mix algoritm is available for 32 40 41 42 44 44 47 49 50 54 59lts Duvet algorithm is available for 55 60 61 62 lts Rapid 15 is available for without twinjet model R...

Страница 3: ...L is visualized on display for 2 sec to indicate child lock activation with tone D buzzer in models having buzzer option After 2 sec CL indication if fixed off and remaining time is visualized on disp...

Страница 4: ...ramps to max spin for 15 seconds While its speed rising up to the maximum speed the EV1 prewash valve is activated for 5 seconds and then the EV2 wash valve is activated for 5 seconds Step3 The motor...

Страница 5: ...8 Flow chart of the autotest During test AU is visualized on display at the end of the test is visualized and door is unlocked During test pressing other buttons makes no change on display...

Страница 6: ...till first level frequency then start heating Heater will be on max 8 minutes If temperature doesn t increase 2 C in 8 minutes machine will give NTC failure E05 Or if the NTC connection is broken the...

Страница 7: ...ation Error Number Indication For User Indication For Service Yes No Yes No Door is not locked E01 Yes Yes Door is unlocked during programme E01 Yes Yes Lack of water E02 Yes Yes Pump failure E03 Yes...

Страница 8: ...y in the next washing process Wrong detergent has been used Use only the detergents produced for full automatic machines The washing result is bad Laundry too dirty for the program you have selected S...

Страница 9: ...intanance pump filter should be cleaned regularly 8 1 1 Technical Features Nominal voltage 220 240 V Nominal current 0 28 A 10 Nominal power 37 W Frequency 50 Hz Resistor coil 130 5 Water flow 17 L mi...

Страница 10: ...ctions Phase notral and ground connections 8 2 1 Technical Features Kind of heating Tubular heating element with NTC sensor Nominal voltage 230 V Nominal power 2000 W 5 Resistance 24 8 5 Thermal fuse...

Страница 11: ...6 5 43 0 48 6 0 33 9 38 1 5 27 0 30 1 10 21 6 23 9 15 17 4 19 1 20 14 1 15 4 25 11 5 12 5 30 9 4 10 2 35 7 8 8 3 40 6 4 6 9 45 5 4 5 7 50 4 5 4 7 55 3 8 3 9 60 3 2 3 3 65 2 7 2 8 70 2 3 2 4 75 1 9 2 0...

Страница 12: ...res Nominal voltage 220 240 V Nominal power 8 VA Frequency 50 60 Hz Rated flow 7 lt min 15 Operating water pressure 0 0 3 1 Mpa 8 4 2 Checking of Component Check the resistance value on the component...

Страница 13: ...of Component 1 Make sure there are no laundry in washing machine tap is connected and opened power cord is plugged Put no detergent in drawer 2 Bring porgram knob to position 1 Cotton 90 C program 3 P...

Страница 14: ...It is essential to check the motor for correct diagnosis and quick servicing In the below picture socket points on the motor is shown to measure with multimeter Motor Socket Terminals Tacho Socket Te...

Страница 15: ...32079 TONLON 2 28 7 NA 70 2 7 32030653 G J 2 28 2 63 NA 60 69 69 83 32037679 KENING 2 10 7 NA 63 6 7 32031043 G J 2 03 2 34 NA 60 69 69 83 32027577 WELLING 2 39 7 NA 66 6 7 32027576 HAIER 2 36 7 NA 68...

Страница 16: ...TC which is assambled in the door lock 8 7 1 Technical Features Lock Time 20 C 2 6 Unlock Time 20 C 35 75 Nominal voltage 220 V Nominal current 16 4 A 8 7 2 Checking of Component Check the resistance...