Prior to installation, units should NOT be stored
outside in corrugated boxes (cardboard boxes) alone.
• Until installation, all units should be placed in a
covered dry storage area. The storage area should
not exceed -40°C (-40°F) to 50°C (122°F).
- This can be preferably in a roofed area or with a
tarp that is secured in such a way to keep water
off of the corrugated boxes (cardboard boxes).
STORAGE
6
MAINTENANCE / CLEANING
5
• To maintain high optical efficiency, occasional
cleaning of the outer lens surface may be needed,
with frequency dependent on local conditions.
•
Use a mild soap or detergent, which is essentially
neutral pH (pH approximately 6 to 8), nonabrasive,
and which contains no chlorinated or aromatic
hydrocarbons.
•
Wash thoroughly, using a soft cloth.
•
Rinse with clean, cold water and wipe dry.
WARNING
Risk of electric shock.
Make certain power is off before
attempting any maintenance.
PHOTOELECTRIC CONTROL:
• (If option present)—Photoelectric control receptacle
should be oriented before control is installed.
•
Loosen the two holding screws and rotate receptacle
until “North” is directed as near as possible to true
North.
•
Tighten holding screws and install control.
PE Dimming Control (If Applicable):
•
No external connections for Dimming are required
when the GE Dimming PE Control and GE Dimming PE
Receptacle is used.
•
All dimming control connections will be made
between the Dimming PE and Luminaire through the
included PE Receptacle.
•
Refer to instructions included with GE Dimming PE
Control regarding appropriate settings for dimming
control.
CAUTION
Ensure the PE socket base gasket is properly seated in the
die casting hole before tightening the holding screws.
SLIPFITTER MOUNTING:
•
Connect Luminaire wire leads to supply wire.
•
Connections are to be made in interior of pole.
•
Replace pole cap. A wiring diagram is provided on a
label inside luminaire for reference.
• For slipfitter units without leads, connections may be
made to terminal board inside fixture.
•
Note that care should be exercised not to pinch leads
between door and housing when closing the door.
ARM MOUNTINGS:
•
Terminal Board is in the Architectural Mounting Arm.
•
Open mounting arm door to gain access to terminal
board.
•
Wire supply leads to terminal board in accordance
with labeling.
•
Close door when wiring is complete.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not
covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting.
g
GE Lighting • 1-888-MY-GE-LED
(1 - 888 - 69 - 43 - 533)
• www.gelighting.com
GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.