2018111-336 Rev. B
eBike III basic / comfort
- 95 -
Bit
15
Bit
14
Bit
13
Bit
12
Bit
1
1
Bit
1
0
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
e
rror
Code
BIts
lIu (l
oad
regulatIon
and
InterfaCe
pCB)
Bit
Error
Reaction
Display / Info
Troubleshooting
0
To high rotation
Warning
none
- advise user to cycle less than 130 rpm
1
Load out of limit
Warning
- advise user to cycle between
30 and 130 rpm
- perform static calibration
2
DMS Offs. invalid
Safety shut down
- perform static calibration OFFSET
- if error persists:
reset DMS default values
- if error persists:
replace strain gauge module
3
DMS Gain invalid
Safety shut down
- perform dynamic calibration
- if error persists:
replace strain gauge module
4
+24V out of range
Internal error
- check power supply
- check connections:
power supply to switch to LIU
cable DTU <-> LIU
5
+5V out of range
Safety shut down
- restart eBike (OFF / ON)
- if error persists: replace LIU
6
Brake not released.
Safety shut down
- check connections:
LIU <-> brake
LIU <-> strain gauge module
- perform static calibration
- if error persists:
reset DMS default values
7
Safety state mode
Safety shut down
- restart eBike (OFF / ON)
- if error persists:
replace LIU
8
Setup not ready
Internal error
- restart eBike (OFF / ON)
- if error persists:
check cable DTU <-> LIU
- check connection between
all PCB (e.g. LIU, SMU, BPU)
- replace LIU
9
CAN zykl. Timeout
Safety shut down
- restart eBike (OFF / ON)
- if error persists:
check cable DTU <-> LIU
- check connection between
all PCB (e.g. LIU, SMU, BPU)
- replace LRE
Содержание eBike III basic Series