- 56 -
eBike III basic / comfort
2018111-336 Rev. B
p
ower
swItCH
replaCeMent
1. The power switch is mounted between the two rear
parts of the ergometer housing.
2. Follow the steps in
“Remove housing of the eBike III basic“ on page 42
or
“Remove housing of the eBike III comfort“ on page
46.
3. Remove the cables from the defect power switch and
place them on the appropriate contacts of the new
switch.
If the cable between switch and LIU board has to be
replaced, open the electronic carrier (underneath the
eBike), disconnect the power cable from the LIU board
and replace it with the spare cable included in the
package..
4. Secure the cables with a cable strap
When reassembling the housing:
5. Slide the plastic cover of the power switch in the
appropriate slot in one side part of the housing.
6. During assembly of the side parts take care, that
the plastic cover of the main switch fits into the
corresponding slot of the other side part.
p
ower
connector
(
from
main
Switch
)
on
liu
board