4
- [EN] English
K393 Issue 3
To start - Set up the settings
When the task is set up (Table 2/3), use the
Settings
menu
to adjust the input and/or output operation.
If there is additional data for a menu option, select
Settings
(
■
■
) to see the values that are set up. If
necessary, adjust the values. Refer to “Edit functions”.
Table 4:
(Part of table) Menu options - Settings (Input)
(Part of table) Menu options - Settings (Input)
To start - Edit functions
Example 1) Set up a label for
x:y Scaling
= %.
Example 2) Set up values for
x:y Scaling
= 0 to 100%.
Display: Task
mA + mA
1
Settings selection
(If applicable)
2
3
■
■
▲
▼
Sk1 = Start/Stop
Sk2 = Settings
Menu:
Settings
4A
5A
6A
Settings
x:y
▲
▼
■
■
[
✓
]/[ ]
Sk1 = Edit
Menu:
Settings
4B
5B
▲
▼
[
●
]/[ ]
Options
(If applicable)
Description
... Units
UPM only = “Pressure Units” if you select an IDOS
task (Table 2/3). Select one of the fixed units of
measurement (psi, mbar ... ).
To include maximum, minimum and average
values for the measurement task.
To select and set up a tare value for the
measurement task (a specified value or the
reading on the display).
The instrument subtracts a positive tare value, and
adds a negative tare value.
Additional data: Select Settings
(
■
■
)
To select and set up a scale of values: One local
scale for each measurement task (Maximum: 5).
Additional data (Example 1/2): Select Settings
(
■
■
)
Options
(If applicable)
Description
To select and set up the filter values to give a
smoother output for the measurement task:
Band as a % of full scale (FS). The filter
compares each new value with the previous
value. If the new value is outside the band, it
is not filtered.
Low pass filter time constant in seconds.
Increase the value to increase damping
factor.
Additional data: Select Settings
(
■
■
)
To select and set up the alarm values for the
measurement task (maximum and minimum).
Additional data: Select Settings
(
■
■
)
UPM only.
Gage sensors or sensors with differential
operation. A zero correction that makes the
instrument read zero at local pressure.
Leak Test only. To set an applicable period for the
leak test (Hours:Minutes:Seconds).
Settings
x:y
1
Edit
2
Edit
3
■
■
▲
▼
■
■
Sk1 = Edit
A3 - item [27]
Edit
...
Edit
4
5
%_
▲
▼
■
■
A3 - item [27]
Settings
x:y
1
Settings
x:y
2
Edit
3
4
▲
▼
■
■
▲
▼
■
■
Sk1 = Edit
= Flow scaling
(mA, pressure only)
Shift
OK
Содержание Druck DPI 832
Страница 2: ......
Страница 6: ...Druck DPI 832 Electrical loop calibrator User manual K393 EN DE ES FR IT PT CN JP RU ...
Страница 7: ......
Страница 20: ...Druck DPI 832 Kalibrator für Elektrische Signale Handbuch K393 EN DE ES FR IT PT CN JP RU ...
Страница 21: ......
Страница 34: ...Druck DPI 832 Calibrador de lazo eléctrico Manual del usuario K393 EN DE ES FR IT PT CN JP RU ...
Страница 35: ......
Страница 48: ...Druck DPI 832 Calibrateur de boucle électrique Manuel d utilisation K393 EN DE ES FR IT PT CN JP RU ...
Страница 49: ......
Страница 62: ...Druck DPI 832 Calibratore di loop elettrico Manuale utente K393 EN DE ES FR IT PT CN JP RU ...
Страница 63: ......
Страница 76: ...Druck DPI 832 Calibrador de loop elétrico Manual do usuário K393 EN DE ES FR IT PT CN JP RU ...
Страница 77: ......
Страница 90: ...Druck DPI 832 电气回路校验仪 用户手册 K393 EN DE ES FR IT PT CN JP RU ...
Страница 91: ......
Страница 104: ...Druck DPI 832 電気ループ校正器 ユーザーマニ ュ アル K393 EN DE ES FR IT PT CN JP RU ...
Страница 105: ......
Страница 116: ...Druck DPI 832 Калибратор электрической токовой петли Руководство пользователя K393 EN DE ES FR IT PT CN JP RU ...
Страница 117: ......
Страница 131: ......