K114 Issue No. 9
Druck ADTS 405 User Manual
3 - 11
3
The ADTS 405 system may now be used but for full specification accuracy and
stability, wait the "WARMUP" period of 15 minutes. The display shows “WARMUP” in the
lower right hand corner, this message clears automatically after the time period.
3.7 Control or Measure Parameter
To change the displayed parameter:
Value parameters -
Press the parameter key
e.g., press
SPEED/Qc
to display airspeed.
Rate parameter
-
Press the associated parameter key followed by the rate
key for that channel. e.g., display airspeed rate, press
SPEED/Qc
then
RATE
.
ROC/Ps Rate
may be directly
pressed without first pressing
ALT/Ps
.
Note:
The displayed parameters depend on the last keys pressed.
To display two parameters:
Press each value parameter in turn.
e.g., display altitude and airspeed together, press
ALT/Ps
then
SPEED/Qc
.
In control mode, an arrow, at the right-hand end of the aim value, indicates
the last parameter selected. This can be changed by entering a new value.
To display a value parameter together with its rate:
Press the parameter key followed by the associated rate key.
e.g., display airspeed and rate of speed together, press
SPEED/Qc
then
RATE
.
See Rate set-up for display details.
Note:
If
ROC/Ps Rate
is pressed, the display automatically shows
ALT
and
ROC
.
Aim
A new aim can be entered using the numeric keys. Each digit is displayed as it is
pressed. The existing aim is replaced when the first digit of the new aim is pressed. If
an error is made during the entry of data, press
CLEAR/QUIT
to restore the original
aim.
Press
ENTER
to action the new aim.
Note 1:
The
000
key can be used as a quick way of entering thousands.
Note 2:
The ADTS 405 must be in control mode to enter a new aim (current aim
displayed). If the aim field shows "Leak Measure" press
LEAK MEASURE/
CONTROL
to enter control mode.
Содержание Druck ADTS 405
Страница 2: ... General Electric Company All rights reserved ...
Страница 4: ...K114 Issue No 9 ...
Страница 32: ...K114 Issue No 9 2 10 Druck ADTS 405 User Manual F IGURE 2 4 ADTS 405 G ENERAL VIEW ...
Страница 33: ...K114 Issue No 9 Installation 2 11 2 F IGURE 2 5 ADTS 405 R EAR P ANEL VIEW ...
Страница 41: ...K114 Issue No 9 Druck ADTS 405 User Manual 3 7 3 Control Mode ...
Страница 43: ...K114 Issue No 9 Druck ADTS 405 User Manual 3 9 3 Go to Ground ...
Страница 50: ...K114 Issue No 9 3 16 Operation FIGURE 3 6 TRIPLE DISPLAY FIGURE 3 5 DUAL DISPLAY ...
Страница 72: ...K114 Issue No 9 4 6 Maintenance INTENTIONALLY LEFT BLANK ...
Страница 92: ...K114 Issue No 9 5 20 Testing and Fault Finding INTENTIONALLY LEFT BLANK ...