March 2008
1-60
Programming Site Data
Entering KV vs. SS Tables
The KV/SS submenu enables you to enter a table of values of the
kinematic viscosity (KV) based on signal strength (SS). You can then
use this table to calculate KV as shown in the KV/SS option (in the
ADVAN
option of the
SETUP
submenu) discussed on page 1-33. To use
the option, you must enter the KV vs. SS pairs in descending order of
KV and ascending order of SS. For example, if pair 1 is KV = 10
centistrokes and SS = 62, then pair 2 must be KV
≤ 10
centistrokes
and SS
≥
62. The DF868 accepts 2 to 20 pairs.
1.
To enter the
GLOBAL
menu, press
[F3]=GLOBL.
1.
To enter the
KV/SS
submenu, press [
→]
and
[F1]
.
2.
Press
[ENT]
to accept the current
# of KV/SS Pairs
or enter a new
value (from 2 to 20) and press
[ENT]
.
3.
Press
[ENT]
to accept the current
Sig Strength
value or enter a new
value (50.0 to 85.0) and press
[ENT]
. Enter the signal strength
values in ascending order.
4.
Press
[ENT]
to accept the current
Kin Viscosity
value or enter a new
value (0.050 to 500.) and press
[ENT]
. Enter the kinematic viscosity
values in descending order.
The
Sig Strength
and
Kin Viscosity
prompts repeat for each pair. After
entering all the pairs, the meter returns to the
Global PROGRAM
menu.
Содержание DigitalFlow DF868
Страница 7: ...Chapter 1 ...
Страница 75: ...Chapter 2 ...
Страница 91: ...Chapter 3 ...
Страница 105: ...Chapter 4 ...
Страница 116: ...Chapter 5 ...
Страница 117: ...Clearing Data Introduction 5 1 Clearing Totalized Data 5 2 Deleting Site Files 5 2 Deleting Log Files 5 3 ...
Страница 121: ...Chapter 6 ...
Страница 132: ...Appendix A ...
Страница 142: ...Appendix B ...
Страница 143: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2 ...
Страница 149: ...Appendix C ...
Страница 169: ...Appendix D ...