![GE Bently Nevada 7200 Series Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/ge/bently-nevada-7200-series/bently-nevada-7200-series_installation-manual_132817027.webp)
14 mm Proximity Transducer System 7200 Series Installation Manual
22
D. Deviation from best straight line -- approximately 20 to 180 mils (0.51 to 4.57 mm). Error is
referenced to the straight line
which is centered to yield minimum error and which has a 100
mV/mil (3.94 V/mm) slope.
Typical
(90%)
Worst Case (99.7%)
E. Gap at -4. 0 Vdc
F. Temperature
Sensitivity
Probe and 1 foot (0.305 metres) of cable
Probe and 9 metres of cable
Cable
Only
Less than ± 4.5 mils (0.11 mm)
Less than ± 6.5 mils (0.17 mm)
40 ± 12 mils (1.02 ± 0.30 mm)
See Appendix C, Figure C-2
See Appendix C, Figure C-3
See Appendix C, Figure C-4
Содержание Bently Nevada 7200 Series
Страница 2: ...Part Number 74756 01 Rev G 07 07 Installation Manual 14 mm Proximity Transducer System 7200 Series ...
Страница 16: ...Section 2 INSTALLATION 11 Figure 2 4 Field Wiring and Shield Grounding for 7000 7200 and 9000 Series Monitors ...
Страница 22: ...APPENDIX A 17 Figure A 1 14 mm Probe Ordering Information ...
Страница 24: ...APPENDIX B 19 Figure A 3 14mm Extension Cable Ordering Information ...
Страница 34: ...APPENDIX C 29 6 APPENDIX C SCALE FACTORS AND SENSITIVITY CURVES ...
Страница 35: ...14 mm Proximity Transducer System 7200 Series Installation Manual 30 Figure C 1 Incremental Scale Factor ...
Страница 36: ...APPENDIX C 31 Figure C 2 Probe and One Foot Cable at Temperature ...
Страница 38: ...APPENDIX C 33 Figure C 4 9 Metres Cable at Temperature ...
Страница 42: ...APPENDIX C 37 Figure C 8 Effects of Flat Surface Side Clearance ...
Страница 43: ...14 mm Proximity Transducer System 7200 Series Installation Manual 38 Figure C 9 Effects of Counterbore ...