14 mm Proximity Transducer System 7200 Series Installation Manual
6
false information will be generated. Side view can be avoided by proper gapping of the probe or by
removing conductive material by counterboring.
Figure 2-2. Proper Probe Tip Side Clearance
Brackets or other structural members used to mount probes must be rigid. When using a mounting
bracket, it should be field checked for resonant frequency. The resonant frequency should be at least
ten times machine running speed. Brackets must support the probe in a position perpendicular to the
observed surface. The probe axis can vary 15 degrees from perpendicular without affecting the
performance of the transducer system.
Probes may be mounted through existing machine hardware such as the bearing cover of a machine
case. Many times it is advantageous to use an external mounting adapter, allowing the probes to be
removed and replaced, or gapped again without taking the machine apart. For more information on
mounting brackets and adapters, contact your nearest Bently Nevada office for information on
transducer accessories.
Содержание Bently Nevada 7200 Series
Страница 2: ...Part Number 74756 01 Rev G 07 07 Installation Manual 14 mm Proximity Transducer System 7200 Series ...
Страница 16: ...Section 2 INSTALLATION 11 Figure 2 4 Field Wiring and Shield Grounding for 7000 7200 and 9000 Series Monitors ...
Страница 22: ...APPENDIX A 17 Figure A 1 14 mm Probe Ordering Information ...
Страница 24: ...APPENDIX B 19 Figure A 3 14mm Extension Cable Ordering Information ...
Страница 34: ...APPENDIX C 29 6 APPENDIX C SCALE FACTORS AND SENSITIVITY CURVES ...
Страница 35: ...14 mm Proximity Transducer System 7200 Series Installation Manual 30 Figure C 1 Incremental Scale Factor ...
Страница 36: ...APPENDIX C 31 Figure C 2 Probe and One Foot Cable at Temperature ...
Страница 38: ...APPENDIX C 33 Figure C 4 9 Metres Cable at Temperature ...
Страница 42: ...APPENDIX C 37 Figure C 8 Effects of Flat Surface Side Clearance ...
Страница 43: ...14 mm Proximity Transducer System 7200 Series Installation Manual 38 Figure C 9 Effects of Counterbore ...