Section 2 - INSTALLATION
5
the observed surface can cause electrical or mechanical runout which will introduce error in the
Proximitor output.
The various techniques for eliminating electrical and mechanical runout are described in several
papers available from Bently Nevada Corporation, including:
•
Dealing with "Glitch". Where does Electronic Vectorial Runout Compensation Fit In?
(Application Note 004)
•
"Glitch": Definition of and Methods for Correction, including Shaft Burnishing to Remove
Electrical Runout. (Application Note 011)
The electromagnetic fields of probe tips mounted too closely together will cross-couple, causing a
small amplitude ac signal to be superimposed on the Proximitor outputs. To prevent cross-coupling
mount the probes so that the distance between the tips is at least as large as that shown in the Figure
2-1.
A = 28 mm (1.1 inches) minimum
B = 82 mm (3.2 inches) minimum
C = 64 mm (2.5 inches) minimum
D = 61 mm (2.4 inches) minimum
Figure 2-1. Cross-Coupling
Because the electromagnetic field also extends outward from the side of the probe tip, it is necessary
to remove all conductive material from around the tip as shown in Figure 2-2. If this is not done,
Содержание Bently Nevada 7200 Series
Страница 2: ...Part Number 74756 01 Rev G 07 07 Installation Manual 14 mm Proximity Transducer System 7200 Series ...
Страница 16: ...Section 2 INSTALLATION 11 Figure 2 4 Field Wiring and Shield Grounding for 7000 7200 and 9000 Series Monitors ...
Страница 22: ...APPENDIX A 17 Figure A 1 14 mm Probe Ordering Information ...
Страница 24: ...APPENDIX B 19 Figure A 3 14mm Extension Cable Ordering Information ...
Страница 34: ...APPENDIX C 29 6 APPENDIX C SCALE FACTORS AND SENSITIVITY CURVES ...
Страница 35: ...14 mm Proximity Transducer System 7200 Series Installation Manual 30 Figure C 1 Incremental Scale Factor ...
Страница 36: ...APPENDIX C 31 Figure C 2 Probe and One Foot Cable at Temperature ...
Страница 38: ...APPENDIX C 33 Figure C 4 9 Metres Cable at Temperature ...
Страница 42: ...APPENDIX C 37 Figure C 8 Effects of Flat Surface Side Clearance ...
Страница 43: ...14 mm Proximity Transducer System 7200 Series Installation Manual 38 Figure C 9 Effects of Counterbore ...