49
—
8.3
Disassembly procedures for outdoor unit 25, 32
Suitable for PRO AIR 109 IN / PRO AIR 109 OUT, PRO AIR 112 IN / PRO AIR 112 OUT
Operation procedures/pictures
Disassembling the top cover
Screw off the one piece of fixing screw that fixes
the handle with screwdriver and push down with
strength to take out the handle.
Screw off the 3 pieces of screws around the top
cover and then lift it upward to take out the top
cover as shown in Fig.8-25.
Disassembling the net cover
Unscrew 4 tapping screws in the screen
enclosure, and remove the screen enclosure as
shown in Fig.8-26.
Disassembling panel
sub-assembly
Unscrew the 5 tapping screws at the valve
support chassis and sideboard of the condenser
to take off panel assembly as shown in Fig.8-27.
Top cover Screw Screw Handle
Fig.8-25
Screw
Net cover
Fig.8-26
Panel
Screw
Fig.8-27
Содержание AIR 326
Страница 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Страница 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Страница 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Страница 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Страница 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Страница 21: ... 20 4 3 Outline and installation dimensions of indoor units 25 32 Handle Unit mm 500 Bolt Nut Spanner ...
Страница 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Страница 75: ... 74 Explosive view of parts and components of outdoor unit ...
Страница 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Страница 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Страница 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Страница 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Страница 101: ... 100 ...