
—
31
—
7.1.3.5 Auto button
The system will be stopped if the button is pressed down when the remote controller is powered on, with
the system being operated by remote controller. If the remote controller is powered off, pressing the button
will enter auto run mode and the swing will be turned on. The system will be running in accordance with
the remote controller if there is remote control command.
7.1.3.6 Sleep function
If the sleep function is set up at cooling or drying mode, T
set
will be raised automatically for 1
℃
after one
hour, and will be raised for another 1
℃
2 hours later. Then, it will be running at such a setting temperature
and such a setting wind speed.
set
Temperature setting T
set
set
set
1 hour 2 hour Over 2 hour
If the sleep function is set up at heating mode, T
set
will be decreased for 1
℃
after one hour, and will be
decreased for 2
℃
2 hours later. Then, it will be running at such a setting temperature and such a setting
wind speed.
1 hour 2 hour Over 2 hour
set
set
Temperature setting T
set
set
In FAN and AUTO mode, the set temperature is fixed.
7.1.3.7 Swing motor control
Use the SWING button of the wireless remote controller to controller SWING On/Off. Swing will only act
when indoor fan is running.
After power on, the stepping motor turns back to 0 position and closes the air outlet vent; after the unit is
turned on, it will turn back to the max. air outlet I position; when in swinging state, it will swing between L
and D position. When the unit is turned off, it will turn back to 0 position.
7.1.3.8 Measurement of maximum cooling capacity, name heating/cooling
Select cooling mode power on with remote controller and press “Light” button to turn on the light. In this
case, a sound from buzzer should be heard. Press “Change air” button to set up for air change 1 (air
change 2), a sound from buzzer should be heard, entering the maximum cooling mode (name cooling).
Afterwards, it is not allowed to press any other button of remote controller. Otherwise, the system will exit
from the maximum cooling mode (name cooling). Select heating mode power on with remote controller
and press “Light” button to turn on the light. In this case, a sound from buzzer should be heard. Press
“Change air” button to set up for air change 1 (air change 2), a sound from buzzer should be heard,
entering the maximum heating mode (name heating). Afterwards, it is not allowed to press any other
button of remote controller. Otherwise, the system will exit from the maximum heating mode (name
heating).
In case the maximum cooling, name cooling and name heating have been properly set up, cancel the
maximum cooling, name cooling and name heating 2 hours later.
Содержание AIR 326
Страница 2: ... 1 Summary and features Model Remark PRO AIR 107 IN PRO AIR 107 OUT 1Ph 230V 50Hz R410A 1 ...
Страница 4: ... 3 Model Remark PRO AIR 218 IN PRO AIR 218 OUT 1Ph 230V 50Hz R410A ...
Страница 5: ... 4 Model Remark GE AIR 326 IN1 GE AIR 326 IN2 GE AIR 326 OUT 1Ph 230V 50Hz R407C ...
Страница 6: ... 5 Model Remark GE AIR 428 IN GE AIR 428 OUT 1Ph 230V 50Hz R407C ...
Страница 20: ... 19 4 2 Outline and installation dimensions of indoor unit 20 Handle 60cm Bolt Nut Spanner ...
Страница 21: ... 20 4 3 Outline and installation dimensions of indoor units 25 32 Handle Unit mm 500 Bolt Nut Spanner ...
Страница 71: ... 70 Explosive view and parts list Explosive view of parts and components of indoor unit 9 ...
Страница 75: ... 74 Explosive view of parts and components of outdoor unit ...
Страница 77: ... 76 Explosive view of parts and components of outdoor unit frequency converter ...
Страница 79: ... 78 Explosive view of parts of outdoor unit one driving two ...
Страница 81: ... 80 Explosive view of parts of outdoor unit one driving three ...
Страница 83: ... 82 Explosive view of parts of outdoor unit one driving four ...
Страница 101: ... 100 ...