20
fuel supply system
Ensure that all fuel pipe connections are tight, secure and
without leaks.
Ensure that all gas line shutoff valves are OPEN and that
adequate fuel pressure is available whenever automatic
operation is desired.
engine oil
The engine is shipped from the factory pre-run and filled
with non-synthetic oil (API SL 10W-30). This allows for system
operation in a wide range of temperature and climate
conditions. Before starting the engine, check oil level and
ensure that engine is serviced as described in the engine
operator’s manual.
coolant system
The engine is shipped from the factory filled with a
50 50 mix of automotive (Dex-Cool™ orange) anti-freeze
and water. This will provide optimum year round protection
against freezing, boiling and corrosion. The coolant system
incorporates a water heater that operates when ambient
temperature is below 80ºF AND utility power is present at the
transfer switch. Periodically check coolant level as described
in the engine manual.
final installation considerations
Battery
The installer must supply and install a valve-regulated
rechargeable starting battery. The starting battery MUST
conform to the specifications shown in this chart.
Battery specifications
Volts
12 Volt DC
Amps (MIN)
650 CCA (cold cranking amps)
Type
Valve Regulated Lead Acid (VRLA)
Terminal Hardware Post
Dimensions (MAX):
Width
7.5 inches (191mm)
Length
11.25 inches (286mm)
Height
10.0 inches (254mm)
install the battery
as described in
Servicing the Battery
in
the
Maintenance
section of the operator’s manual. Always
make sure the
neGatiVe
cable is connected last.
NOTICE
Any attempt to crank or start the engine before it has
been properly serviced with the recommended oil will result in
equipment failure.
Refer to
•
Maintenance
in the Operator’s Manual and engine
manual for oil fill information.
Damage to equipment resulting from failure to follow this
•
instruction will void engine and generator warranty.
WarninG
Battery posts, terminals and related accessories
contain lead and lead compounds, chemicals known to the state
of california to cause cancer and reproductive harm. Wash
hands after handling.