70
TransNET OEM Integration Guide
05-3946A01, Rev. C
Table 30. Transceiver Connector J3 Pinouts
Payload data RS-485; Diagnostic data RS-232
Pin No.
Input/
Output
Signal
Type
Name/Description
1
IN
—
Ground
—Connects to ground (negative supply poten-
tial).
2
OUT
RS-232
Diagnostic TXD
—Supplies received diagnostic/ad-
ministrative data to the connected device.
3
OUT
TTL, 3 Vdc
Alarm condition
—A low indicates normal operation.
A high indicates an alarm. (See ASENSE [HI/LO]
command for more information.)
4
IN
RS-232
Diagnostic RXD
—Accepts diagnostic/administrative
data from the connected device.
5
IN
—
DC Input (6–30 Vdc)
—
Supply Source must be capa-
ble of furnishing at least 7.5 watts.
6
IN
TTL, 3 Vdc
Sleep Mode Input
—A ground on this pin turns off
most circuits in a remote radio. This allows for greatly
reduced power consumption, yet preserves the radio’s
ability to be brought quickly back on line. See
the Radio’s Sleep Mode (Remote Units Only)” on
Page 26
for details.
7
OUT
TTL, 3 Vdc
Data Carrier Detect (DCD)—
A low indicates hop-
ping synchronization has been achieved.
8
IN
TTL, 3 Vdc
Power Supply Shutdown Control—
A ground on this
pin causes the OEM module’s power supply to shut
down.
9
—
—
Reserved—Do not connect.
10
IN
Differential
RXD+/RXA (Transmitted Data+)
—Non-inverting
receiver input. Accepts payload data from the connect-
ed device.
11
IN
—
DC Input (6–30 Vdc)
—
Supply Source must be capa-
ble of furnishing at least 7.5 watts.
12
IN
Differential
RXD–/RXA (Transmitted Data-)
—Inverting receiv-
er input.
13
—
—
Reserved—Do not connect.
14
OUT
Differential
TXD+/TXA (Received Data+)
—Non-inverting driver
output. Supplies received payload data to the connect-
ed device.
15
IN
—
Ground—
Connects to ground (negative supply poten-
tial).
16
OUT
Differential
TXD–/TXA (Received Data-)
—Inverting driver out-
put.