05-3946A01, Rev. C
TransNET OEM Integration Guide
51
RTU [ON, OFF, 0-80]
Remote Terminal Unit Simulator
This command re-enables or disables the radio’s internal RTU simulator,
which runs with factory-proprietary polling programs (poll.exe and
rsim.exe). The internal RTU simulator is available whenever a radio has diag-
nostics enabled. This command also sets the RTU address to which the radio
will respond.
The internal RTU can be used for testing system payload data or pseudo bit
error rate (BER) testing. It can be helpful in isolating a problem to either the
external RTU or the radio. The default RTU setting is
OFF
.
RX [xxxx]
Radio Receive Test Frequency
This command sets or displays the test receive frequency used in place of
hopping when the radio is in
SETUP
mode. The test receive frequency can be
reprogrammed to any value between 902.200 MHz and 927.800 MHz, inclu-
sive. The factory default setting is 915.000 MHz.
RXD [0–255]
RXD Delay
Used to set a delay, in milliseconds, of RXD data to emulate a seamless mode
with much lower latency in applications where retries are not required. Use a
delay of twice the value of the
HOPTIME
).
RXTOT [NONE, 0–1440]
Receive Data Timeout-Timer
This command sets or displays the amount of time (in minutes) to wait for the
next received data packet before issuing a receiver time-out alarm. The
default setting is
NONE
.
SAF [ON, OFF]
Store-and-Forward Services Support
This command enables/disables the operation of the Store-and-Forward
services. It can be set only at the network’s Master station, but will effect all
radios in the associated network. The default setting is OFF. See related
commands:
“XMAP [00000000-FFFFFFFF]” on Page 55
.
SETUP
Setup Radio Test
This command sets up the transceiver for checking antenna SWR or trans-
mitter power with external measuring equipment. Do not use this mode
during normal operation.
When the
SETUP
command is entered, the prompt changes to
SETUP>
, and:
• Hopping is disabled.
Содержание TransNET OEM EL806
Страница 12: ...x TransNET OEM Integration Guide 05 3946A01 Rev C ...
Страница 97: ...05 3946A01 Rev C TransNET OEM Integration Guide 85 ...
Страница 98: ...86 TransNET OEM Integration Guide 05 3946A01 Rev C ...
Страница 110: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway ...