76
TransNET OEM Integration Guide
05-3946A01, Rev. C
Do not apply DC power to the transceiver without first attach-
ing a proper RF load, or the transceiver may be damaged.
DC Power Connector, J3
This connector accepts operating power for the transceiver. A wall-style AC
adapter (Part No. 01-3862A02) is recommended for this service.
DC connection is made with a 2-pin polarized plug, GE MDS Part No.
73-1194A39. Be sure to observe proper polarity.
The left terminal is posi-
tive (+) and the right is negative (–)
. (See
).
The radio transceiver and OEM Evaluation PCB must be used
only with negative-ground systems operating between 6 and
30 Vdc. Make certain that the polarity of the power source is
correct.
Invisible
place
holder
Figure 21. DC Power Connector (P/N 73-1194A39)
NOTE:
Although the power connector used on the OEM Evaluation Board resem-
bles those used by some earlier MDS transceivers, such as the MDS 9810 and x710
family, the connectors are
not
equal and the use of the wrong plug will provide unre-
liable connections. Only the power connector shown in
with screw termi-
nals and two retainer screws should be used with the OEM Evaluation Board.
Diagnostic Connection, J4
J4 is an RJ-11-6 modular connector used to connect the evaluation
board/transceiver to a PC terminal for programming and interrogation. An
RJ-11 to DB-9 Adapter Cable (Part No. 03-3246A01) is required for this
connection. If desired, an cable may be constructed for this purpose as shown
in
. Only Pins 4, 5, and 6 of the RJ-11 connector should be used.
Pins 1, 2, and 3 are reserved for factory test purposes.)
The data parameters of the
diagnostics
port are as follows: 8 data bits, 1 stop
bit, and no parity. It automatically configures itself to function at 1200, 2400,
4800, 9600, 19200, 38400, 57600, and 115200 bps, as required.
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
Lead
Screws (2)
Binding
Wire Ports (2)
(Polarity: Left +, Right –)
Retaining
Screws (2)
Содержание TransNET OEM EL806
Страница 12: ...x TransNET OEM Integration Guide 05 3946A01 Rev C ...
Страница 97: ...05 3946A01 Rev C TransNET OEM Integration Guide 85 ...
Страница 98: ...86 TransNET OEM Integration Guide 05 3946A01 Rev C ...
Страница 110: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway ...