– 36 –
Note:
When servicing the inverter, it is important
to dress the wiring to keep low-voltage DC wiring
and 120 VAC wiring separate.
To remove the inverter:
1. Unplug the unit.
2. Open access cover.
3. Loosen the 2 hex-head bolts that hold the
inverter in place.
4. Disconnect the 2 wiring harnesses from the
left side of the inverter.
4. Slide the inverter to the right to disengage the
holding tabs.
Note:
It may be necessary to bend the process
tube in order to remove the inverter. If it is
necessary to bend the process tube, use extreme
care.
5. Slide the inverter out of the machine
compartment.
To remove the inverter cover:
Use a small screwdriver to release the two small
tabs and carefully remove the inverter cover.
Wiring Harness
Wiring Harness
Bolt
Bolt
Compressor Lead
Wires
Compressor Lead
Wires
Signal Wire Connector
(From Main Control Board)
Inverter
Inverter
Signal Wire Connector
(From Main Control Board)
Line-In (L1)
Line-In (L1)
Tabs