– 18 –
Drain Pan Fan
The Monogram Bottom Mount has an auxiliary
evaporation fan located under the unit. The
purpose of this fan is to improve the evaporation
rate of drain water should extreme conditions
occur.
Should this fan malfunction, there is no
replacement procedure. The absence of this fan
will not affect drain water evaporation under
normal conditions. A stainless steel hot gas loop
routed through the drain pan will provide ample
evaporation.
To remove the fan
1. Remove toe kick (2 screws).
2. Slide out and remove drain pan.
3. Disconnect harness from fan motor.
4. Remove fan by unscrewing 2 screws
accessible from within the pan housing.
DEFROST SYSTEM
Adaptive Defrost
Adaptive Defrost can be described as a defrost
system that adapts to a refrigerator’s surrounding
environment and household usage.
Unlike conventional defrost systems that use
electromechanical timers with a fixed defrost cycle
time, Adaptive Defrost utilizes an intelligent,
electronic control to determine when the defrost
cycle is necessary. In order to accomplish the
correct defrost cycle time, the main control board
monitors the following refrigerator operations:
•
Length of time the refrigerator doors were open
since the last defrost cycle
•
Length of time the compressor has run since
the last defrost cycle
•
Amount of time the defrost heaters were on in
the last defrost cycle
Adaptive Defrost is divided into 4 separate cycles.
Those operations are:
•
Cooling Operation
•
Pre-Chill Operation
•
Defrost Heater Operation
•
Dwell Period