– 5 –
TECHNICAL DATA
Temperature Control...........................WR55X10098
Lamp Overtemperature Thermostat..WR50X10003
Defrost Heater Overtemperature
Thermostat.............WR50X10030
Defrost Heater....................................WR51X10015
Condenser Fan Motor.........................WR60X10053
Condenser Fan Blade........................WR60X10049
Evaporator Fan Motor.........................WR60X10043
Evaporator Fan Blade.........................WR60X10050
Main Board..........................................WR55X10433
Thermistors (2-FF, 1-FZ, 1-EV)..........WR55X10028
Drain Pan Fan Motor...........................WR60X10106
Damper...............................................WR09X10065
Evaporator...........................................WR85X10007
Compressor........................................WR87X10064
Condenser..........................................WR84X10030
Dryer.....................................................WR86X0096
Inverter................................................WR55X10155
DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
CAUTION
To avoid personal injury when servicing the
condensing unit, stand on a ladder which will give
enough support to allow removal of the top panel
and safely allow access to service the unit.
Max Defrost Control
W/No Door Openings ..................... 60 hrs @ 40 min
Evap Defrost Thermo Disc ............................... 65-45
°
F
Light Thermostat. .......................................... 190-130
°
F
Electrical Rating: 115V AC 60 Hz ..................... 9.0 amp
Maximum Current Leakage ............................. 0.75 mA
Maximum Ground Path Resistance .......... 0.14 Ohms
Energy Consumption .......................... 39 KWhr/month
ELECTRICAL SPECIFICATIONS
NO LOAD PERFORMANCE
CONTROL POSITION 37-0
°
F and
AMBIENT TEMPERATURE OF
70
°
F
90
°
F
Fresh Food,
°
F .............................. 35-39 ............... 35-39
Frozen Food,
°
F .......................... (-4) +4 ............. (-4) +4
Percent Running Time ...................... 60 .................... 80
REFRIGERATION DIAGNOSIS
To access the
low pressure
side of the system, install a
WJ56X61
valve
only
on the process tube extending
from the compressor case.
COMPRESSOR
GREEN/YELLOW
GREEN/YELLOW
BLACK
ORANGE
GROUND
TO CABINET
WIRING
COMMUNICATION
SIGNAL
RED
WHITE
GROUND
INVERTER
BLACK
BLUE
BROWN
IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability
in connection with its use.
REPLACEMENT PARTS
Compressor ................................................. 833 BTU/hr
Minimum Compressor Capacity
Vacuum, ..................................................... 22 inches
Minimum Equalized Pressure
@ 70
°
F ..................................................... 60/65 PSIG
@ 90
°
F ..................................................... 79/80 PSIG
R134a Refrig. Chg. ........................................... 13.00 oz
REFRIGERATION SYSTEM
Sealed System
CONDENSER
COMPRESSOR
INVERTER*
PROCESS TUBE
DRYER
SUCTION TUBE
EVAPORATOR
CONDENSER LOOP
CAPILLARY
*Approximate
location of
inverter
Содержание ZIC360NR
Страница 32: ... 32 Evaporator Fan Motor Evaporator Fan Connector Evaporator Fan Compressor and Inverter ...
Страница 41: ... 41 Illustrated Parts ...
Страница 42: ... 42 ...
Страница 43: ... 43 ...
Страница 44: ... 44 ...
Страница 45: ... 45 ...