GLOSSARY

Consult Instruction for use. 

Suitable for Home care 

Caution! 

BF-type equipment / Nasal canula 

connection

Keep away from heat and 

flammable material

Oxygen supply connection

Keep away from oil 

and grease

SN

Serial number 

Upper and lower humidity limit

REF

Order number 

Upper and lower temperature limit 

Fragile 

Keep dry

Manufacturer 

Date of manufacture

LOT

Batch number

Inlet parameter

Use by

Outlet parameter 

Take back equipment for recycling. 

Do not dispose equipment into 

unsorted municipal waste 

WARRANTY

The Standard Warranty period is two years from date of receipt by the GCE Customer (or if this is 

not known 2 years from  time of the product manufacture shown on the product).
The standard warranty is only valid for products handled according to Instruction for use (IFU) and 

general industry good practice and standards.

10

.

11

.

0434

MANUFACTURER: 

GCE s.r.o. Tel :   

+420 569 661 111

Zizkova 381 Fax :  

+420 569 661 602 

583 81 Chotebor  

http://www.gcegroup.com 

Czech Republic  

© GCE s.r.o.

Содержание ECOlite4000

Страница 1: ...EN Page 1 12 ECOlite 4000 GAS SAVER INSTRUCTION FOR USE...

Страница 2: ...om the oxygen The dosage and timing of oxygen delivery is controlled by a microprocessor in accordance with the chosen setting Dosage per breath is independent of breathing rate therefore additional o...

Страница 3: ...TIONS At atmospheric pressure up to 60 oxygen is harmless 100 oxygen produces a cough after 6 hours and increasing breathlessness after 25 hours PERSONNEL INSTRUCTIONS AND TRAINING According to Medica...

Страница 4: ...function from national standards In the event of any problem with connection please contact the distributor the manufacturer Display screen ON OFF button Oxygen inlet Outlet into cannula Control butt...

Страница 5: ...clean If the unit is being used with an oxygen supply source with adjustable fl ow rates set the flow rate on the supply source to 4 litres per minute or to the closest setting above Check the cylinde...

Страница 6: ...s the button and hold it down Afterwards press the ON OFF button and also hold it down A PRESS KEY sign will appear Press the two buttons marked and simultaneously a LANGUAGE sign will appear Using th...

Страница 7: ...ngly Activate the alarm by not breathing in the cannula After approx 1 minute the alarm should set off both by sound and an alert on the display If there is an abnormal sound noise gas leakage or any...

Страница 8: ...void wasting oxygen 6 4 2 DISCONNECTING THE DEVICE Before disconnecting the ECOlite 4000 from the gas source Close the oxygen supply from the cylinder reservoir disconnect the connector of the spiral...

Страница 9: ...At the end of the product s life time 10 years at most the ECOlite 4000 device must be withdrawn from service To prevent reuse the owner shall make the ECOlite 4000 impossible to use or return it to...

Страница 10: ...c Area EEA This mark on the product indicates compliance with Directive 93 42 EEC relating to medical devices Class IIa Functional performance Sensitivity 0 13 cm of H2O Setting Manual automatic Trigg...

Страница 11: ...eter Use by Outlet parameter Take back equipment for recycling Do not dispose equipment into unsorted municipal waste WARRANTY The Standard Warranty period is two years from date of receipt by the GCE...

Страница 12: ...Asia The company operates 15 subsidiaries around the world and employs more than 850 people GCE Group includes four business areas Cutting Welding Process Applications Medical and High Purity Today s...

Отзывы: