7.3
Connecting the LED fixture to the mains
Warning! Make sure mains power is switched off.
Warning! Ensure the cord is not coiled and does not touch any hot surfaces.
Warning! Connect the cables according to local rules, safety regulations and electrical code.
Warning! Ensure external switching gear can cope with the inrush current of the LED fixture (see section 3.2). Always use a
double pole contactor suitable for switching a capacitive load. Never use household timers to switch the LED fixture!
•
Connect the Wieland RST 16i5 female connector on the power cable to the Wieland RST16i5 male connector on the LED
fixture (fig. 7).
•
Connect the power cable to the mains (fig. 8). Ensure use of the appropriate power cord for the NEMA socket. Please
reference section 3.3 for compatible power cords.
Cable description 2400e LED 120V / 277V, and 240V:
Wire
120 V, 277 V
240 V
White
Neutral (N)
Line (L1)
Black
Phase (L)
Line (L2 )
Green
Ground ( )
Ground ( )
•
Switch on mains power.
Warning! Do not connect or disconnect the power cable to the LED
fixture while under load.