background image

14  |  

User Guide  |  Working with the Simulator  |

You can perform an average of 200 

needle sticks with a 22 gauge needle 

by utilizing the entire surface area of 

the injectable sites.

Note that the use of needles larger 

than 22 gauge will reduce the skin/

vein life.

WARNING

Use only Gaumard’s provided 

simulated blood. Any other simulated 

blood brand may contain sugar 

or other additives that may cause 

blockages and interrupt the bleeding 

system.

DRAINING THE SYSTEM

WARNING

At the end of every simulation session, 

you must purge the IV system with 

clean water. If the training arm is not 

going to be used for a week or more, 

purge the system with a solution of 

isopropyl alcohol in distilled water. 

Failure to do so may permanently 

damage the system.

INSTRUCTIONS FOR USE

1.  Close all clamps.
2.  Disconnect  the  A&V  in-flow  tube  and  the 

arterial recirculation tube.

3.  Connect  the  second  drainage  tube  to  the 

arterial recirculation port.

4.  Open both clamps on the drainages tubes.
5.  Fill the syringe with filling tube with distilled 

water and connect it to the A&V in-flow port 

on the arm.

6.  Slowly inject fluid into the system.
We  recommend  flushing  veins  with  70:30 

solution of clean water to isopropyl alcohol (IPA) 

at least once per month to prolong the life of the 

vasculature.

7.  Disconnect the syringe with filling tube.
8.  Repeat  steps  6-7  with  air  until  all  fluid  has 

been drained from the arm.

9.  Close all the clamps and disconnect all ports.

INTRAMUSCULAR AND SUBCUTANEOUS 
EXERCISES

The training arm includes an incision and suture 

insert in the upper arm to perform intramuscular 

injections, incisions and suturing exercises.

Both  the  Incision  and  Suture  Insert  and  the 

A&V  insert  are  multilayer,  consisting  of  the 

skin, subcutaneous tissue, and muscle, so they 

provide a platform to train incision and suturing.

Interchange the inserts according to the training 

procedure.

There  are  also  two  subcutaneous  injection 

sides  located  in  the  volar  forearm  and  lateral 

upper arm.

Содержание S402.100

Страница 1: ...raining Arm S402 100 Gaumard Simulators for Health Care Education Arterial and Venous Patient Training Arm is an interactive educational system developed to assist a certified instructor It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making ...

Страница 2: ...2 User Guide Arterial and Venous Training Arm ...

Страница 3: ...p Simulator Set Up 9 Priming The System 10 Working with the Simulator Arterial and Venous Exercises 13 Draining The System 14 Intramuscular and Subcutaneous Exercises 14 Replacing the Incision and Suture Insert 15 Injections In The Dorsum of The Hand 15 Hemodialysis exercises 15 Replacements 18 Skin Replacement 18 Vein Replacement 20 Consumables and Replacements 22 Selected Parts List 22 Warranty ...

Страница 4: ...4 User Guide Care and Cautions Care and Cautions ...

Страница 5: ...r storage may damage the simulator Keep it stored in the box and or bag provided Store the simulator in a cool dry place extended storage should be between 32 85 degrees F 0 29 Celsius Other temperatures will cause the simulator to soften and slowly warp Do not stack or store heavy materials on top of the box and or bag It is acceptable to operate the simulator at an ambient temperature of 95 degr...

Страница 6: ...6 User Guide Getting Started Getting Started ...

Страница 7: ...injections Incisions and suture placement exercises at the bicep sites Surgical interventions such as the placement of an AV graft or AV fistula Hemodialysis through the utilization of the fistula insert installed in the forearm APPEARANCE Medium skin tone is the standard simulator color light or dark skin is available at no extra cost SIMULATOR Full size adult arm with replaceable veins and skin ...

Страница 8: ...8 User Guide Equipment Set Up Equipment Set Up ...

Страница 9: ...rterial and venous A V in flow port white 4 Arterial recirculation port black 5 Drainage port black 5 Close both clamps on the A V in flow tube and arterial recirculation tube 6 Fill the blood dispensing bag with simulated blood or water by placing the provided funnel into the upper port and dispensing the fluid Use water initially and once you are familiar with the simulator use the simulated blo...

Страница 10: ...la insert are secure 13 Turn the pulse rate and strength controls counter clockwise so they are set to their minimum values The training arm is completely assembled proceed to the Priming The System Section to fill the system PRIMING THE SYSTEM 1 Locate the IV filling kit One syringe with filling tube Two drainage tubes with clamps 2 Connect the two drainage tubes to the arterial recirculation por...

Страница 11: ...e strength control to maximum value As the fluid is circulated air bubbles entrapped will be flushed from the arterial recirculation tube to the dispensing bag If there is no fluid circulation or the pulse is not working please check the tubes to ensure that there are no kinks and both clamps are open If everything is correctly setup and still there is no circulation then repeat the priming proced...

Страница 12: ...12 User Guide Working with the Simulator Working with the Simulator ...

Страница 13: ...s can be performed in all vessels including the arterial ones The radial and brachial artery can be converted to the veins by turning the pump controls to their minimum value and disconnecting the power supply INSTRUCTIONS FOR USE If the system hasn t been primed refer to the Priming the System section above Notice that these instructions are applicable for the both the SMASH arm S402 100 and S263...

Страница 14: ...nage tube to the arterial recirculation port 4 Open both clamps on the drainages tubes 5 Fill the syringe with filling tube with distilled water and connect it to the A V in flow port on the arm 6 Slowly inject fluid into the system We recommend flushing veins with 70 30 solution of clean water to isopropyl alcohol IPA at least once per month to prolong the life of the vasculature 7 Disconnect the...

Страница 15: ...ON AND SUTURE INSERT 1 Lift up one side of the insert and carefully remove it 2 Hold the replacement Incision and Suture insert over the new vacant slot 3 Orient the S on the Incision and Suture insert to face towards the shoulder 4 Place the insert and massage the sides to smooth the transition between insert and skin INJECTIONS IN THE DORSUM OF THE HAND Three veins are supplied in the dorsum of ...

Страница 16: ...ement 7 Orient the wider end of the replacement insert with the proximal side 8 Align and position the edges of the skin to smooth the transition between skin and insert 9 Direct the male connectors of the wider end of the insert into the proximal female connectors on the arm 10 Repeat steps 7 and 8 for the insert s distal side 11 Ensure that all connections are secure ...

Страница 17: ... Appendix User Guide 17 Appendix ...

Страница 18: ...orts located on the arm 4 Remove the dispensing bag from the metal stand 5 Disconnect wrist band with the snaps holding the training arm in place 6 Use the Allen key provided to remove the upper bolt from the shoulder 7 Gently lift the arm and release it completely from the base 8 Keep the shoulder base pad and the nut in position as shown below 9 Remove the arterial and venous or fistula insert 1...

Страница 19: ...hen reinstalling the bolt described in the step 6 ensure the shoulder hole is clear to avoid pinching any tubing inside WARNING Do not use sharp objects or fingernails as they will puncture or tear the skin 12 If at this point you wish to perform the IV replacement refer to the IV Replacement section below 13 To install the new skin apply talcum powder inside the skin to aid with the process 14 Pl...

Страница 20: ... the female connector in the respective end of the tube 13 Follow the same instructions to replace the veins from the dorsum of the hand VEIN REPLACEMENT To replace the veins used in the arm follow the instructions listed below 1 Gather the following items Replacement vein set Talcum powder Clear tape 2 Refer to the Skin Replacement section above to remove the skin prior to start this section 3 Re...

Страница 21: ...position as there were originally 15 Refer to steps 12 15 from the Skin Replacement section to place the skin back into position 16 Proceed to the Priming the System section as replacing the vein will introduce air into the system and it will need to be re primed ...

Страница 22: ...cription S402 100 911 L M D Arterial and Venous Insert S402 100 912 L M D Fistula Insert S402 100 913 L M D Incision and Suture Insert 1308044 5 6 7 A Arm Skin S402 100 810 Replacement Vein Set S402 100 985 Vein Filling Kit S402 100 812 Synthetic Blood Concentrate S402 100 948 Talcum Powder S402 100 968 Power Supply with Cord S402 100 906 Shoulder Base Pad S402 100 811 Dispensing Bag ...

Страница 23: ...able Any subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by Gaumard This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties For example third party products such as computers desktop...

Страница 24: ... USA Office hours Monday Friday 8 30am 4 30pm EST GMT 5 4 Summer Time General Information Gaumard ZOE Michelle Mike PEDI Susie Simon Susie Simon Code Blue SIMA Models SIMA GYN AID Virtual Instruments Codemaker Code Blue NOELLE Simulation Made Easy HAL eCPR Zack RITA Chloe Seatbelt Susie Krash Kids Premie UNI Omni SmartSkin are Trademarks of Gaumard Scientific Company 2019 All rights reserved Gauma...

Отзывы: