| Equipment Set Up | User Guide |
9
SIMULATOR SET UP
To set up the Arterial and Venous Patient
Training Arm follow the instructions below:
1. Gather the following items:
•
Training arm installed in the Lucite® base
with metal stand
•
Dispensing bag
•
Arterial and venous in-flow tube (white
connector)
•
Arterial recirculation tube (black connector)
2. Rotate the metal stand into position as
shown below.
3. Place the blood dispensing bag on the
metal stand as shown below
4. Connect the arterial and venous in-flow tube
and the arterial recirculation tube to the outlet
ports in lower section of the dispensing bag.
Port and tubing classification:
1
Arterial and venous (A&V) in-flow tube (white
connector)
2
Arterial recirculation tube (black connector)
3
Arterial and venous (A&V) in-flow port (white)
4
Arterial recirculation port (black)
5
Drainage port (black)
5. Close both clamps on the A&V in-flow tube
and arterial recirculation tube.
6. Fill the blood dispensing bag with simulated
blood or water by placing the provided funnel
into the upper port and dispensing the fluid.
Use water initially and once you are familiar with
the simulator, use the simulated blood.
In a separate container, mix a solution of
Gaumard simulated blood colorant and water
following the mixing instructions on the bottle.
WARNING
Use only Gaumard’s provided
simulated blood. Any other simulated
blood brand may contain sugar
or other additives that may cause
blockages and interrupt the bleeding
system.
7. Connect the stopper to upper port on the
dispensing bag.
8. Place the end of both tubes in a container
and open the clamps.
9. When you start to see the blood flow out of
tubes, proceed to close the clamps.
5
4
3
2
1
Содержание S402.100
Страница 2: ...2 User Guide Arterial and Venous Training Arm ...
Страница 4: ...4 User Guide Care and Cautions Care and Cautions ...
Страница 6: ...6 User Guide Getting Started Getting Started ...
Страница 8: ...8 User Guide Equipment Set Up Equipment Set Up ...
Страница 12: ...12 User Guide Working with the Simulator Working with the Simulator ...
Страница 17: ... Appendix User Guide 17 Appendix ...