background image

|  Care and Cautions  |  User Guide  |  

5

Overall Warnings

Damage  caused  by  misuse  may  void  the 

manufacturer’s warranty. Failure to comply with 

the following guidelines may result in injury or 

damage to the equipment. Additional warnings 

are found throughout the document.

GENERAL

This  simulator  is  constructed  of  material

that  approximates  skin  texture.  Therefore,

in  handling  the  model,  use  the  same  gentle

techniques  as  you  would  in  working  with  a

patient.

Do  not  wrap  this  or  any  other  Gaumard

product in newsprint.

Indelible marks made with ballpoint pens, ink

or marker cannot be removed.

Do  not  use  alcohol,  acetone,  Betadine®  or

any other antiseptic which contains iodine in this

or  any  Gaumard®  simulator.  These  products

could damage or stain the skin of the simulator.

Use of needles sizes 22 gauge and smaller

will extend the lifetime of the resealing skin and

tubing.

STORAGE

Improper storage may damage the simulator.

 

Keep it stored in the box and/or bag provided.

Store  the  simulator  in  a  cool,  dry  place.

 

extended storage should be between 32 - 85 

degrees F (0-29 Celsius). Other temperatures 

will cause the simulator to soften and slowly 

warp.

Do not stack or store heavy materials on top

 

of the box and/or bag.

It is acceptable to operate the simulator at an

 

ambient temperature of 95 degrees Fahrenheit

 

(35 Celsius) for a short period of time. 

CLEANING

Clean  the  skin  of  the  simulator  after  every

training  session.  The  skin  should  be  cleaned

with a cloth, dampened with diluted liquid dish

washing soap.

Always purge with clean distilled water and

then drain the vein reservoirs at the end of the

simulation  session.  Doing  so  will  retard  the

formation  of mold  and  prevent  clogging  of the

system.

We  recommend  flushing  veins  with  70:30

solution of clean water to isopropyl alcohol (IPA)

at least once per month to prolong the life of the

vasculature.
The  simulator  is  “splash-proof”  but  not  water-

proof.  Do not submerge or allow water to enter 

the interior of the simulator.

Содержание S402.100

Страница 1: ...raining Arm S402 100 Gaumard Simulators for Health Care Education Arterial and Venous Patient Training Arm is an interactive educational system developed to assist a certified instructor It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making ...

Страница 2: ...2 User Guide Arterial and Venous Training Arm ...

Страница 3: ...p Simulator Set Up 9 Priming The System 10 Working with the Simulator Arterial and Venous Exercises 13 Draining The System 14 Intramuscular and Subcutaneous Exercises 14 Replacing the Incision and Suture Insert 15 Injections In The Dorsum of The Hand 15 Hemodialysis exercises 15 Replacements 18 Skin Replacement 18 Vein Replacement 20 Consumables and Replacements 22 Selected Parts List 22 Warranty ...

Страница 4: ...4 User Guide Care and Cautions Care and Cautions ...

Страница 5: ...r storage may damage the simulator Keep it stored in the box and or bag provided Store the simulator in a cool dry place extended storage should be between 32 85 degrees F 0 29 Celsius Other temperatures will cause the simulator to soften and slowly warp Do not stack or store heavy materials on top of the box and or bag It is acceptable to operate the simulator at an ambient temperature of 95 degr...

Страница 6: ...6 User Guide Getting Started Getting Started ...

Страница 7: ...injections Incisions and suture placement exercises at the bicep sites Surgical interventions such as the placement of an AV graft or AV fistula Hemodialysis through the utilization of the fistula insert installed in the forearm APPEARANCE Medium skin tone is the standard simulator color light or dark skin is available at no extra cost SIMULATOR Full size adult arm with replaceable veins and skin ...

Страница 8: ...8 User Guide Equipment Set Up Equipment Set Up ...

Страница 9: ...rterial and venous A V in flow port white 4 Arterial recirculation port black 5 Drainage port black 5 Close both clamps on the A V in flow tube and arterial recirculation tube 6 Fill the blood dispensing bag with simulated blood or water by placing the provided funnel into the upper port and dispensing the fluid Use water initially and once you are familiar with the simulator use the simulated blo...

Страница 10: ...la insert are secure 13 Turn the pulse rate and strength controls counter clockwise so they are set to their minimum values The training arm is completely assembled proceed to the Priming The System Section to fill the system PRIMING THE SYSTEM 1 Locate the IV filling kit One syringe with filling tube Two drainage tubes with clamps 2 Connect the two drainage tubes to the arterial recirculation por...

Страница 11: ...e strength control to maximum value As the fluid is circulated air bubbles entrapped will be flushed from the arterial recirculation tube to the dispensing bag If there is no fluid circulation or the pulse is not working please check the tubes to ensure that there are no kinks and both clamps are open If everything is correctly setup and still there is no circulation then repeat the priming proced...

Страница 12: ...12 User Guide Working with the Simulator Working with the Simulator ...

Страница 13: ...s can be performed in all vessels including the arterial ones The radial and brachial artery can be converted to the veins by turning the pump controls to their minimum value and disconnecting the power supply INSTRUCTIONS FOR USE If the system hasn t been primed refer to the Priming the System section above Notice that these instructions are applicable for the both the SMASH arm S402 100 and S263...

Страница 14: ...nage tube to the arterial recirculation port 4 Open both clamps on the drainages tubes 5 Fill the syringe with filling tube with distilled water and connect it to the A V in flow port on the arm 6 Slowly inject fluid into the system We recommend flushing veins with 70 30 solution of clean water to isopropyl alcohol IPA at least once per month to prolong the life of the vasculature 7 Disconnect the...

Страница 15: ...ON AND SUTURE INSERT 1 Lift up one side of the insert and carefully remove it 2 Hold the replacement Incision and Suture insert over the new vacant slot 3 Orient the S on the Incision and Suture insert to face towards the shoulder 4 Place the insert and massage the sides to smooth the transition between insert and skin INJECTIONS IN THE DORSUM OF THE HAND Three veins are supplied in the dorsum of ...

Страница 16: ...ement 7 Orient the wider end of the replacement insert with the proximal side 8 Align and position the edges of the skin to smooth the transition between skin and insert 9 Direct the male connectors of the wider end of the insert into the proximal female connectors on the arm 10 Repeat steps 7 and 8 for the insert s distal side 11 Ensure that all connections are secure ...

Страница 17: ... Appendix User Guide 17 Appendix ...

Страница 18: ...orts located on the arm 4 Remove the dispensing bag from the metal stand 5 Disconnect wrist band with the snaps holding the training arm in place 6 Use the Allen key provided to remove the upper bolt from the shoulder 7 Gently lift the arm and release it completely from the base 8 Keep the shoulder base pad and the nut in position as shown below 9 Remove the arterial and venous or fistula insert 1...

Страница 19: ...hen reinstalling the bolt described in the step 6 ensure the shoulder hole is clear to avoid pinching any tubing inside WARNING Do not use sharp objects or fingernails as they will puncture or tear the skin 12 If at this point you wish to perform the IV replacement refer to the IV Replacement section below 13 To install the new skin apply talcum powder inside the skin to aid with the process 14 Pl...

Страница 20: ... the female connector in the respective end of the tube 13 Follow the same instructions to replace the veins from the dorsum of the hand VEIN REPLACEMENT To replace the veins used in the arm follow the instructions listed below 1 Gather the following items Replacement vein set Talcum powder Clear tape 2 Refer to the Skin Replacement section above to remove the skin prior to start this section 3 Re...

Страница 21: ...position as there were originally 15 Refer to steps 12 15 from the Skin Replacement section to place the skin back into position 16 Proceed to the Priming the System section as replacing the vein will introduce air into the system and it will need to be re primed ...

Страница 22: ...cription S402 100 911 L M D Arterial and Venous Insert S402 100 912 L M D Fistula Insert S402 100 913 L M D Incision and Suture Insert 1308044 5 6 7 A Arm Skin S402 100 810 Replacement Vein Set S402 100 985 Vein Filling Kit S402 100 812 Synthetic Blood Concentrate S402 100 948 Talcum Powder S402 100 968 Power Supply with Cord S402 100 906 Shoulder Base Pad S402 100 811 Dispensing Bag ...

Страница 23: ...able Any subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by Gaumard This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties For example third party products such as computers desktop...

Страница 24: ... USA Office hours Monday Friday 8 30am 4 30pm EST GMT 5 4 Summer Time General Information Gaumard ZOE Michelle Mike PEDI Susie Simon Susie Simon Code Blue SIMA Models SIMA GYN AID Virtual Instruments Codemaker Code Blue NOELLE Simulation Made Easy HAL eCPR Zack RITA Chloe Seatbelt Susie Krash Kids Premie UNI Omni SmartSkin are Trademarks of Gaumard Scientific Company 2019 All rights reserved Gauma...

Отзывы: