![GATmatic TWC-1600 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/gatmatic/twc-1600/twc-1600_instruction-manual_4330416005.webp)
TIRE CHANGER FOR TRUCK TWC-1600
4
It is not essential to anchor the machine to the floor however, the floor must be
smooth and permit the platform rollers to move freely.
ELECTRIC HOOK UP
Before making any electric hook up, check to be certain that the mains
voltage corresponds to that stamped on the voltage tag (attached to the
cord near the tire changer’s plug).
It is absolutely essential that:
-the system is equipped with a good grounding circuit.
-The machine is connected to a power supply line circuit breaker set for
30 mA.
-The current in-stake is adequately protected against over-currents with
fuses or automatic magneto-thermic switch with rated values as shown in
the table.
Note the required power draw as high-lighted on the data plate fixed to
the tire changer. Check to make sure the shop electric wiring circuit is
dimensioned sufficiently to carry this.
Manufacturer shall not be liable for any injury to persons or damage to
things caused by failure to comply with these regulations and can cancel
warranty coverage.
SENSE OF ROTATION CHECKS
power supply
Rated current
Fuse
Switch
220v-3ph-50/60Hz.
10A
16A
Work on the electric system, even if minor, must be done
exclusively by professionally qualified personnel.