Instructions for DKC500ACL/DKC800ACL
www.gatexpertstore.com
16
DIP Switch Adjustment
All changes to these settings must be completed by a licensed electrician
Figure 17
Number Function
Description
1
Soft Start/Close
Function
OFF–enabled
ON–disabled
Default position is OFF.
2
Limit Switch Setting
OFF–Normal Open
ON–Normal Close
Default position is ON, this should align with limit
switch and is not recommended to be modified by
the users.
3
Automatic Close Time
Setting
Automatic close time setting: the gate is operated to
open by remote control operation and will close
automatically after a few seconds delay.
3 OFF 4 ON: automatic close delay time is 12s.
3 ON 4 OFF: automatic close delay time is 24s.
3 ON 4 ON: automatic close delay time is 36s.
3 OFF 4 OFF: no automatic close function.
Default setting: 3 OFF 4 OFF
Disable the automatic close function.
4
5
Auto-reverse Function
OFF-enable
ON-disable
Default position is OFF, this should align with the
opener status and is not recommended to be
modified by the users.
6
Remote Control Mode
Switch
OFF-single channel mode
ON-four channel mode