34 Maintaining and Troubleshooting the Gateway ALR 9200 Server
8.
Pull the two tabs attached to the single edge contact (SEC) cartridge
(visible after you remove the bracket—C in Figure 6) straight away
from the system board. As you do, the cartridge disengages from the
connector on the system board.
Figure 6: Removing a Processor
9.
Slide the SEC cartridge straight away from the system board, out of
the retention module. Put it on a piece of conductive foam and store it
in an antistatic package.
10.
Remove the replacement processor cartridge from its protective
wrapping.
11.
Orient the SEC cartridge so that the heat sink faces away from the
center of the system board.
If you are installing a termination card assembly, orient it so that the
side with the label faces toward the center of the system board.
Tab on SEC cartridge
Retention module guide rails
SEC cartridge
Processor heat sink
Tab on SEC cartridge
Retention module guide rails
3424.boo Page 34 Wednesday, September 2, 1998 9:23 AM