Enable
DEFAULT SETTINGS:
▪
Checkbox - Unselected
Alarm Type
DEFAULT SETTINGS:
▪
Alarm
Trigger
Click the
(Setup)
button under Trigger to
display the Trigger setup screen.
Level Speed Range
–
numeric text field to
enter the speed range in MPH.
DEFAULT SETTINGS:
▪
20~50 MPH
Sensitivity
DEFAULT SETTINGS:
▪
Middle
Duration
DEFAULT SETTINGS:
▪
0 seconds
Debounce Time -
Multiple alarms of the same
source activated within the debounce time
frame are regarded as one alarm. Numeric text
field to select debounce time from 0 to 10
Seconds
DEFAULT SETTINGS:
▪
0 seconds
Linkage
Click the
(Setup)
button under Linkage to go
to the Linkage setup screen. This sets up the
video display, recording and snapshot options
associated with this alarm.
The Linkage setup screen enables you to
configure the following options:
▪
Channel
–
checkboxes which allow you
to select any combination of the
camera channels to be included in the
display and recording.
▪
Pre Recording
–
numeric value box
which allows you to enter the duration
for which video will be recorded prior