www.gastron.com
08
_
09
4. Name and Description of Each Part
4.1. Components
3.3. Electrical Specifications (Standard Type)
ITEMS
SPECIFICATION
Input Voltage(Standard)
※ Customer supplied PSU must meet
requirements IEC1010-1 and CE
Marking requirements.
Absolute min:
Nominal:
Absolute max:
Ripple maximum allowed:
18V
24V
31V
1V pk-pk
Wattage
Max. wattage:
Max. current:
5.5W @+24 VDC
230mA @+24 VDC
Analog output Current
0-20 mA(500 ohms max load)
All readings ± 0.2mA
Measured-value signal:
4mA(Zero) to 20 mA(Full Scale)
Fault:
0-100% LEL:
100-109%LEL:
Over 110% LEL:
Maintenance:
0mA
4mA - 20mA
20mA - 21.4mA
22mA
3mA
Analog output current ripple & noise max
±20uA
Relay contact
Alarm1, Alarm2, Fault Relay
Rated 1.0 A @ 30VDC or 0.5 A @ 125 VAC
Wiring requirement
Power
CVVS or CVVSB with shield
Analog
CVVS or CVVSB with shield
RS485
STP(Shielded Twisted Pair)
Cable Connection Length
Analog
2500m
RS485
1000m
EMC Protection:
Complies with EN50270
3.4. Environmental Specifications
ITEMS
SPECIFICATION
Operation Temperature
Transmitter
-20 to 60 ℃
Sensor
Refer to Sensor Specification
Storage Temperature
Transmitter
-20 to 60 ℃
Sensor
Refer to Sensor Specification
Operation Humidity
Transmitter
5 to 99% RH (Non-condensing)
Sensor
Refer to Sensor Specification
Pressure Range
90 to 110KPa
Max. air velocity
6m/s
3. Specification
GTD-3000TxW
Instruction Manual
[Figure 2. GTD-3000TxW Components]
NO
NAME
DESCRIPTIONS
1
Housing
Protects PCB Board built in Sensor and Housing from external environmental change and shock.
2
Main PCB
It amplifies output signal from the sensor and converts and send it into DC 4~20 mA standard output.
Isolation RS-485 network signal and alarm relay contact signal are outputted. Also, it sends data for
the display.
3
Display PCB
It displays data received from main PCB on LCD or OLED and displays the current event status with
power lamp, alarm lamp, trouble lamp.
4
Power/Signal Terminal
CN1 consists DC18-24 V power supply and DC 4~20 mA standard output connection terminal (VISO,
+24V, mA,-, ETH).
5
Alarm signal Terminal
CN10 is alarm signal connection terminal, which outputs trouble, alarm1, alarm2 relay contacts.