background image

Working voltage

Power consumption

Methane gas sensor

Methane alarm threshold

Carbon monoxide sensor

CO measuring range

Detected gas

Sensitivity 

Working temperature

Sound level

Sizes

Weight

Enclosure material

Enclosure color

220 V/50Hz

3W

Catalytic

10%LEL

Electrochemical

Carbon monoxide

30 - 300ppm

>

 

40

ppm

о

0 - 40 С

85 

dB

130 х 95 х 37 мм

0,

230kg

ABS

White

 (

RAL 9003)

This instruction manual contains important information for the proper installation 
and  use  of  gas  detector  for 

methane  and 

carbon  monoxide.  Read  the  manual 

carefully before installation and keep it for future issues.

FEATURES:

-Long life electrochemical sensor for CO;
-Catalytic sensor for CH detection
-Quick and easy installation;
-Signalizations of increased gas concentration;
-Signalization for sensor fault;

-

Possibility for

 temporarily 

sound 

mute;

-TEST mode.

TECHNICAL SPECIFICATIONS

CARBON MONOXIDE - DESCRIPTION

Carbon  monoxide  gas  is  colorless  and  odorless.  Inhalation  CO  binds  to 
hemoglobin in the blood, to prevent the spreading of oxygen in the body. Higher 
concentrations lead to death within a few minutes. Common sources of CO are 
motor vehicles, stoves, fireplaces, barbecues, grills.

LOCATION AND POSITIONING OF THE GAS DETECTOR

It is advisable to install a 1 gas detector in each bedroom. Must also be installed 1 
gas detector in all areas of suspected sources of CO - central heating boiler rooms 
with stoves, fireplaces, kitchens, garages. The unit should be mounted at a height 
not less than 1.5 meters above the floor and no higher than 30cm from the highest 
point  of  ceiling.  The  unit  should  not  be  installed  near  the  kitchen  appliances, 
behind curtains, in areas with strong currents of air, just above the sink or stove.

CAUTION: 

This gas detector indicates the presence of gas to the sensor, but gas 

can be found in other areas where it can not be detected. This gas detector is used to 
detect gas regardless of the source of the issue. It is not suitable to detect smoke, 
fire or other gases. Gas detectors intended for use only in closed spaces. Do not use 
outdoors.

INSTALLATION:

 

Install the unit in a controlled area on a carrier or directly on the wall.

To install the gas detector:

                                                                 
- Use the mounting holes and through 2 mounting screws and dowels secure unit.
- Open the plastic housing of the appliance by pressing the pin in the bottom of the 
vessel and the subsequent lifting of the lid.

ELECTRICAL CONNECTIONS:

OPERATION:

INITIAL WAITING

 -  self-preparation. Lasts 60 seconds.Green LED flashes.

NORMAL OPERATION

 - Green LED illuminates.

ALARM-CH4

 - Indication of the presence of CH4 gas. Green LED illuminates. 

The first 5 seconds red LED-CH4 flashes. After 5 seconds - red LED-CH4 lit 
permanently,the unit emits a continuous sound and activates the CH4 relay output.

ALARM-CO

 - Indication of the presence of CO gas. Green LED illuminates. The 

first 5 seconds red LED-CO flashes. After 5 seconds red LED-CO lit permanently, 
the unit emits a intermittent sound and activates the CO relay output.

ALARM-CH4+CO

 - Indication of the presence of CH4 and CO gas. Green LED 

illuminates.  The  red  LED-CH4  and  LED-CO  lit,  the  unit  emits  consistently 
interrupted and continuous sound. Both CH4 and CO relays are activated.

CH4 SENSOR FAULT

 - yellow LED is blinking. Red LED-CH4 is blinking. The 

device produces short sound signals.

CO SENSOR FAULT

 - yellow LED is blinking. Red LED-CO is blinking. The 

device produces short sound signals.

PAUSE

 - After pressing the button. Green LED flashes. Sound and relays output 

are OFF. This mode lasts 5 minutes and can be terminated earlier by pressing the 
TEST button.

TEST

 - Press and hold the button till the specific sound is heard. The instrument 

makes  self  test  that  lasts  20seconds  and  automatically  enters  NORMAL 
OPERATION mode.

MAINTENANCE OF GAS DETECTOR

To  ensure  long  and  trouble-free  operation  test  device  at  least  once  a  month 
(procedure TEST). Once a month, clean the appliance from dust with a vacuum 
cleaner, brush or damp cloth. When cleaning do not use solvents.

SYMPTOMS OF CARBON MONOXIDE POISONING

With limited exposure - slight headache, nausea, vomiting, fatigue.
With  an  average  exposure  -  severe  throbbing  headache,  drowsiness,  rapid 
heartbeat.
At high exposure - convulsions, unconsciousness, cessation of circulation, heart 
failure, death.
In most cases of CO poisoning victims people are conscious but helpless. The 
biggest damage in young children.

IN CASE OF ACTIVATION OF THE GAS DETECTOR

-Immediately take care of fresh air - open all doors and windows and exit the 
room.
-Make sure that all the people there.
-Do not go back into

 the room

 until it is fully aired and gas alarm is not triggered.

-If you feel even the slightest signs of poisoning, immediately contact emergency 
services.
If,  within  24  hours  of  the  alarm  recurs,  perform  these  tasks  again  and  call  a 
specialist to discover the source of CA.

ATTENTION! Activation of the gas detector is an indication of the presence 
of carbon monoxide

 or methane

. This can be deadly.

CD-99  
DOUBLE GAS DETECTOR CH4+CO

 

GB 

CD 99

CD 99

L    N

CO

CH4

N.O.
E.V.

220V~

Fan

1  

 2   

 

3   

 

4  

 5

       6     7     8

CH4   CO

Отзывы: