MULTIPLE WALK-THROUGH OPERATION
Each PD 6500 must be free from interference from adjoining walk-through metal detec-
tors. To ensure that there is no interference, observe the bar graph of one walk-through
while switching the remaining walk-through(s) from
OFF
to
OPERATE
. If a walk-
through’s bar graph continues flickering, a different set-up may be needed.
There are several ways to install multiple walk-throughs in close proximity. The follow-
ing examples are aimed to help the installer determine an appropriate method.
11.3.1.
CASE 1
Description:
•
Two or more PD 6500s that interfere with each other
•
Both units plugged into the same AC power line (same circuit breaker)
Procedure
:
1
. Set all PD 6500’s to
MASTER.
2
. Set end unit (i.e., first or last in a series of PD 6500s) to
CHANNEL 1.
3
. Set next unit to
CHANNEL 2.
4
. Set next unit to
CHANNEL 3.
5
. Repeat pattern for channels 1,2, and 3 for any additional PD 6500s.
11.3.2.
CASE 2:
Description:
•
Two or more PD 6500s that interfere with each other.
•
PD 6500s not plugged into the same AC power line or those with battery back-up
option which may be required to operate in the absence of AC power.
Figure 11-2
PD 6500
Controller
Board
Setting
1
2
3