Table 4–1
Self Test: Possible Failures and Remedies
Failure
Verify and/or replace
Special Note
*
TX A FAIL
1. Panel A cables & connectors
2. Transmitter control board
3. Panel A
*
TX B FAIL
1. Panel B cables and connectors
2. Transmitter control board
3. Panel B
NO SLAVE OUTPUT
1. Verify connections to slave unit
2. Verify TX board
SLAVE SYNC
1. Verify connections from master unit
2. Verify TX board
SYNC FAIL
1. Power connections to TX board
2. Power supply module
3. Transmitter control board
AC SYNC FAIL
Ensure line voltage is
between 100 and 240 VAC.
TX OPTIC FAIL
TX optic board assembly in panel A
RX OPTIC FAIL
RX optic board assembly in panel B
Ensure no
TX OPTIC FAIL
or blockage of IR beam
at waist level of archway.
*
POWER MOD FAIL
Power module
Ensure line voltage is
between 100 and 240 VAC.
*
RXA BOARD FAIL
40-pin cable connection to top board
and top-board cable
*
RXB BOARD FAIL
40-pin cable connection to middle board
and middle-board cable
RXA Z
n
# BAL FAIL
1. Cable and connector to panel A
Ensure no large metal object
2. Top board
nearby. If necessary, move
(# = zone with balance failure)
object or relocate PD 6500.
RXB Z
n
# BAL FAIL
1. Cable and connector to panel B
Ensure no large metal object
2. Middle board
nearby. If necessary, move
(# = zone with balance failure)
object or relocate PD 6500.
*
RXA Z
n
# PK FAIL
1. Panel A cable and connectors
Ensure no
TX A
or
B FAIL.
2. Top board, panel A
*
RXB Z
n
# PK FAIL
1. Panel B cable and connectors
Ensure no
TX A
or
B FAIL.
2. Middle board, panel B
*CABLE
Ensure that the cables attached to the top and middle circuit boards are
MISCONNECT
connected as described in the inside cover of the controller module.
*
Critical failure; PD 6500 cannot operate properly. Correct IMMEDIATELY.