11.3.1.
CASE I
Description:
¥
Two (2) units which interfere with each other;
¥
Both units plugged into same power line (same circuit breaker).
Procedure:
¥
Set both units to
MASTER
;
¥
Set one unit to
CHANNEL A
;
¥
Set one unit to
CHANNEL B
.
11.3.2.
CASE II:
Description:
¥
Three (3) or more units that interfere with each other;
¥
All units plugged into same power (same circuit breaker).
Procedure:
¥
Set next unit to
CHANNEL D
;
Repeat pattern of
CHANNELS A,C, and D
for any additional units.
11.3.3.
CASE III:
Description:
¥
Three (3) or more units that interfere with each other;
¥
Units not plugged into the same power line or units with battery back-up option
which may be required to operate in the absence of AC power.
¥
With the exception of the first and last units, the SH-3 jumper must be removed.
This jumper is located on the Controller Board Assembly. Refer to the drawing for
exact location.
Procedure:
¥
Disconnect units from power line;
¥
Open Access Door of Detection Unit;