10.10.
OPERATORS RESPONSIBILITIES
¥
The primary responsibility of any operator is to follow all instructions of supervisors.
¥
These directives will govern the response of operators to alarms and other situations
that will be encountered. The basic continuing responsibility of the operator will be to
ensure that the Magnascanner CS 5000 operates properly at all times as indicated by
its LCD panel and that
ALL
alarms are investigated.
¥
Remember that the cause of every alarm
MUST
be determined.
10.11.
OPERATORS INSTRUCTIONS
All personnel who are associated with the detector should watch a video presentation
on the Magnascanner CS 5000 in addition to studying this Operator s Manual. Carefully
following the instructions in the Manual will help ensure the security of any facility this
walk-through detector is expected to protect.
As described in the CONTROLS section of this manual, Magnascanner controls are
located in the top section of the archway. If the green
READY
light is not visible on the
control panel, press the
OPERATE
touchpad. Operators can also adjust volume of the
alarm and can reset the traffic counter.
10.12.
READY LIGHT
The green
READY
light, located at the top center of the Control Panel indicates that
the Magnascanner is operating. When the green light is showing, power has been
turned on and the unit is prepared to detect metal.
The green
READY
light must always be on before anyone is permitted to enter the
archway for inspection.
The green light will wink whenever anyone breaks the optical beam across the arch-
way or whenever there is a noise spike. If the green
READY
light should ever go off
and remain off, however, the operator should immediately press the
OPERATE
touch-
pad. The detector will then institute a self-test program with results reported on the LCD
display. All traffic through the unit must be halted until the green
READY
light again
appears and remains constant.
10.13.
DIAGNOSTIC PROBLEMS
Operators should follow instructions of supervisors concerning their response to any
faults ever discovered by the Magnascanner CS 5000 in its self-diagnostic program.
Two situations that can be immediately remedied by operators will be indicated by
Error
3
and
Error 4
on the LCD Panel.
¥
IR Fail (Error 3):
Some obstruction within the unit may be blocking the optical sensor
that projects across the archway. Operator should make certain that the openings for
the optical sensor on each side of the archway, approximately 30 inches from the floor,
have not been blocked in any way.
29
MAGNASCANNER CS 5000
OWNER S MANUAL
' 2000GARRETT METAL DETECTORS, INC.
4/30/00
PN 11674XX
Revised