INSTALLATIONS

It is advisable to leave 1000mm free space on each side and 500mm on the top and the 
bottom of the chargingstation if it is surrounded by a wall. This free space is mandatory for 
charging station’s ventilation.
Never block the air flow.

Содержание 353899

Страница 1: ...GARO Atle Quick Start Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se GARO AB manual 380265...

Страница 2: ...tor 6 AC socket outlet Type 2 7 Emergency Stop button 8 Output cable 9 10 11 Key locks Connector support Output CHAdeMO DC connector 1 1 Antennas 2 7 touchscreen display 3 RFID reader 4 Emergency Stop...

Страница 3: ...ower module lid 10 CCU board 11 Distribution board 12 Output plate cable gland 13 Key locker 4 1 Antennas 2 External fans for heat exchanger 3 Hood stand 4 Key locker 5 12V power supply 6 AC powershar...

Страница 4: ...ard 14 Output plate cable glan 15 Key locker 6 Internal view lower level ATLE CCS or CHAdeMO 1 8kW Module slave 1 2 8kW Module slave 0 3 8kW Module master 4 AC input configuration board 5 Connection t...

Страница 5: ...mpliance Derating As a direct correlation exists between the current and ambient temperature a derating curve is provided for all charging station Minutes before derating VOUT 370VDC IOUT 65A Max Powe...

Страница 6: ...sable to leave 1000mm free space on each side and 500mm on the top and the bottom of the chargingstation if it is surrounded by a wall This free space is mandatory for charging station s ventilation N...

Страница 7: ...model and serial number 7 Warranty does not cover damage occurred by incorrect use of equipment use of any non original spare parts lack of maintenance or faults caused by disassembly of the product...

Страница 8: ...DEMO 12 GARO ATLE CCS CHADEMO 12 WALLBOX INSTALLATION 13 GUN HOLDER INSTALLATION 14 GARO ATLE CCS OR CHADEMO 15 GARO ATLE CCS CHADEMO 15 ELECTRICAL CONNECTION 16 AC INPUT CONFIGURATION 16 ELECTRICAL C...

Страница 9: ...ll pertinent state regional and local safety regulations must be observed when installing and using this product For reasons of safety and to help ensure compliance with documented system data only th...

Страница 10: ...sure or the EV connectors are broken cracked opened or show any other indication of damage This equipment employs parts such as switches and relays that tend to produce arcs or sparks and therefore wh...

Страница 11: ...ncy 95 Nom Harmonic current nominal network voltage THDi 13 Max SPECIFICATION Mains supplies 3 phase P1 P2 P3 GND 3x208 240V AC Mains 3 phase voltage range V AC 208 240 V AC 10 Earthed electrical syst...

Страница 12: ...ting Car Plug connector Plug 1 CCS Plug 2 CHAdeMO Output cable length 3 50 Meters AC output for GARO ATLE CCS CHAdeMO AC only AC output AC Output voltage V AC_nom 400 V 10 AC Output current I AC_max 3...

Страница 13: ...t A s 75 000 Circuit breaker for AC circuit 50A curve C Max time for DC line discharge 60V T 60V 1 s Embedded Insulation device of charger module Response time tan 3sec for asymmetrical fault 62sec f...

Страница 14: ...1920 MHz to 1980 MHz Rx 2110 MHz to 2170 MHz Power Output GSM900 33 0dBm DCS1800 29 3dBm 23 06dBm for 880 915MHz 21 92dBm for 1920 1980MHz RFID reader characteristics To start a charge users must swip...

Страница 15: ...0 of 2017 EN 61000 3 11 EN 61000 3 12 Insulation Monitor Device IMD IEC 61557 1 IEC 61557 8 RoHS 2011 65 EU Declaration of conformity CE 4 Yes EV Ready Pending 1 Max output current will be adapted ve...

Страница 16: ...to avoid the deterioration of non energized electronic components Storage Transport Throughout the transport phase take all necessary measures to keep the pallet stable Equipment Handling GARO ATLE CC...

Страница 17: ...e lid in place and lift the lid and sidewalls upwards 2 Remove the lid of crate You will use it to put the charging station 3 Remove the T30 screw x1 to remove the side panel 4 Remove the M6 nuts x3 o...

Страница 18: ...its bracket Note Charging station must be handled by two people minimum 7b Remove the charging station from its bracket Note Charging station must be handled with lifting equipment GARO ATLE CCS or C...

Страница 19: ...dle the charging station WALLBOX INSTALLATION Wall mounting 4 Tighten the M6 nuts x2 on bracket s studs Recommended torque 4 Nm 5 Place the side panel and fix it with its T30 screw Recommended torque...

Страница 20: ...in 4 Screw by hand the positioning pins FXVIS018322 x2 5 Peel the adhesive protection on the gun holder bracket 6 Place the gun holder bracket on the side of the Wallbox aligned with its positioning p...

Страница 21: ...aligned with its studs 13 Fix the gun holder with its M8 nuts x4 14a Place the DC output connector on the gun holder 14b Place the DC output connector onto the gun holder 15 Repeat the operations for...

Страница 22: ...be connected AC INPUT CONFIGURATION Each connecting point should be individually considered and protected by a residual current device RCD the charging station ensure only supplementary protection by...

Страница 23: ...valent a 30mA Type A or B RCD Wiring must be at 5x16mm minimum flexible conductor 5x25mm maximum rigid conductor 1 Remove 15mm of insulation from the end of the power cable to be connected to the inte...

Страница 24: ...HAZARD OF ELECTRIC SHOCK EXPLOSION OR ARC FLASH Be sure the supply power is off before starting installation Make sure nobody can switch on power during installation Failure to follow these instructio...

Страница 25: ...ath or serious injury 6 Remove 15mm of insulation from the end of the power cable to be connected to the internal circuit breaker 7 Connect ground wire to connection terminal block 8 Connect neutral t...

Страница 26: ...necting point of the unit shall be protected by a 50A tetrapolar MCB C curve or equivalent a 30mA Type A or B RCD Wiring must be at 5x16mm minimum flexible conductor 5x25mm maximum rigid conductor GAR...

Страница 27: ...ed It will startup perform a self test and will display on its screen when ready to use HAZARD OF ELECTRIC SHOCK EXPLOSION OR ARC FLASH Be sure the supply power is off before starting installation Mak...

Страница 28: ...braid in the area shown below during the closing of the door 6 Lock the door 2 keylocks GARO Atle is either sold as a stand alone wallbox or is connected to a backend operator via OCPP The connection...

Страница 29: ...up of the charging station if the CCU does not work Please see the maintenance manual Booting errors Power limitation Configuration parameters details Expected value type Default value Description Pow...

Страница 30: ...le follow these steps 1 A With the same card that the session was initiated with swipe over the card reader or B Remotely stop the charge through an application linked to the backend 2 The display wil...

Страница 31: ...on screen is displayed When an user wants to recharge the electrical vehicle there are 2 ways to identify on the charging station to swipe an activated RFID card once across the card reader or to remo...

Страница 32: ...charging station parameters to the electrical vehicle Note Applicable in CCS CHAdeMO and AC type 2 Note Applicable in CCS and CHAdeMO EV charge CCS or CHAdeMO During the charge of the electrical vehic...

Страница 33: ...ng station performs multiple control steps before disconnecting the vehicle CCS When the CCS protocol is used the user can unplug the vehicle once the charge is done CHAdeMO When the CHAdeMO protocol...

Страница 34: ...jected by the backend server Charger offline Set up to refuse offline charging Charger offline Error timeout Please unplug your vehicle then identify Time out user identified unplug the vehicle before...

Страница 35: ...ll reboot now Station is being rebooted Station rebooted Please unplug your vehicle CCS only Station rebooted during a charge Please unplug and retry to launch the charge Warning insulation failure Ca...

Страница 36: ...in CHAdeMO The charging station is overheating Please unplug your vehicle and check that no air vent is clogged Error occurred 0x0A 0x86 The charging station is overheating Check that no air vent is...

Страница 37: ...r vehicle raised an error Please check error message in the vehicle and unplug your vehicle Not in CHAdeMO Your vehicle raised an error Please check error message in the vehicle and unplug it Error oc...

Страница 38: ...s product has been optimized to reduce the amount of waste produced at the end of their useful life and for better recovery of component parts and materials when following customary processing procedu...

Отзывы: