First booting
During the first power up of the charging station, the following messages will appear on-screen:
If the display does not turn on during power up, please see the maintenance manual.
After booting, check that the charging station is connected on the backend server. If not, please see the maintenance manual.
Message
Description
Error connecting server.
Message displayed during the startup of the charging
station if the backend server rejects the connection.
Error connecting to RFID reader.
Message displayed during the startup of the charging
station if the RFID does not work. Please see the
maintenance manual.
Error connecting to control unit.
Message displayed during the startup of the charging station if the
CCU does not work. Please see the maintenance manual.
Booting errors
Power limitation
Configuration parameters details Expected value type
Default value
Description
PowerLimit
Watts
24000
Maximum power to be
delivered by the charger.
Allow to limit the output power
below 24kW.
VoltageSupplyLimit V
Volt
230
The nominal value of the
single-phase voltage provided
in the country. Usually 230V in
Europe.
CurrentInputLimit
Amp
40
The maximum current allowed
by the power supply
installation (value of the circuit-
breaker installed
outside the charger).
If necessary, you can limit the power delivered by the charging station on the backend server.
For the charging station, use the OCPP frame “Change Configuration” to adjust the following configuration parameters:
Refer to your backend server instructions to know how to change these configuration parameters.