SECTION 1: System Introduction
This manual is designed to help you through the installation process of the PC-900G®
Alarm Panel. We suggest that you read this manual, in its entirety, before beginning
the installation process so that you can better understand all that this security system
has to offer. This manual is not intended for end users. End users are recommended
to read the User Manual provided with the system. If you have any questions regar-
ding the procedures described in this manual, please log on to www.garnet.com.ar/
Soporte_Tecnico/Consultas.
1.1 Specifications Programming
• Local programming via keypads.
• Local programming via PC-Link cable (adapter cable).
• Remote programming via Wifi and COM-900 / COM-904 with AC4 and AC4 softwa
-
re with the Garnet Programmer App.
Partitions
The system has 4 independent partitions, as well as the possibility of sharing zones
in any of them, obtaining partitions with zones common to 4 partitions.
Flexible Zone Configuration
• 32 fully programmable zones with 19 different operating configurations and 8
different, individual attributes for each zone.
• 1 additional zone for each keypad installed.
• Zone circuit with single RFL.
• Fire zones with fault discrimination and alarm.
• Using EXP-8Z zone expanders, the system supports up to 24 zones.
additional cabling (max. 3 expanders)
• With KPD-860RF/G-LCD732RF keypads (one is sufficient), the system supports up
to 24 wireless zones (out of 32 available).
• Crossing areas
• Zones of Group Inhibition
Codes
The equipment has 38 codes available for the following functions:
• 1 master code.
• 31 user codes.
• 4 duress codes (individual for each partition).
• 1 installer code.
• 1 Local Programming Code by Cable Adapter (PC-Link).
Data Bus: BUS-D485
It works through the RS-485 protocol, its connection is made using 4 wires, 2 for
power supply and 2 for data. The system is able to supervise each device connec-
ted to the bus and generate a fault in the event of an error condition.
The maximum connection distance between the panel and the devices is 200
metres.
• Supports up to 8 keyboards.
• 3 EXP-8Z Expander modules.
• 1 Auxiliary Power Supply 1.5A FRA-200
• 1 Adapter cable for local programming (PC-Link).
Modular connection
It is specially designed for the transmission of events via the cellular network.
The PC-900G panel has a female pin bed to which the additional COM-900 / COM-
904 module is connected and provides an additional communication path.
Audible Alarm Output.
The system supports up to 5 alarm outputs, using a combination of Outputs
Programmable PGMs (PGMs) and the Outdoor Siren Output.
Each programmable output can be configured as a siren output for any of the 4
partitions, so that 4 siren outputs (independent to each partition), and an external
siren output common to all 4 partitions could be obtained through the panel’s
Siren Output.
The siren sound is continuous or pulsating in the event of a fire alarm.
The fire alarm can be configured to be Pulse (1 second on, 1 second off) or Temporary
3, according to NFPA 72 standard (500mS on, 500mS off, 500mS on, 500mS off, 500mS
on, 500mS off, 500mS on),1.5 secs. off).
• 1 1.4A, 12VDC Outdoor Siren output. Supervised for short circuit and
disconnection.
G-LED732/G-LCD732/
G-LCD-732RF
Ver conexionado
de PGM
EXP-8Z
Bateria
Transformador
Rojo +
Negro -
16.5 VAC
25 VA
50/60 Hz
A
B
E1 C E2 E3 C E4 E5 C E6 E7 C E8
-
+
+ BUS - A B Z MIC
Magnético
RFL
2.2K
N.C.
N.C.
N.O.
N.O.
RFL
2.2K
RFL
2.2K
RFL
2.2K
SIRENA
1.4A Max.
STATUS
RUNNING
BUS-D485
- AUX + + BELL -
+ BUS -
A B PGM1 PGM2 PGM3 PGM4 Z1
Z6
Z7
Z8
C
C
Z5
Z4
C
Z3
Z2
C
AC
+ BA
T -
ANT WIFI COMUNIC
ANT WIFI
COMUNIC
SIGNAL 1-5
NO SIGNAL
ACK
NAK
RFL
2.2K