background image

HD-3WXL Operation and Installation Manual 

14

 

 

 

 

WARRANTY 

GARNER PRODUCTS, INC. LIMITED WARRANTY 

AND 

WARRANTY RETURN POLICY 

 

Garner Products, Inc. 

(“Garner”)

 

warrants this Garner-branded product against defects in materials and workmanship under 

normal use for a period of ONE (1) YEAR from the date of purchase by the original end-user as evidenced by original end-user’s 
packing slip or invoice (“Warranty Period”).  If a defect arises and a valid claim is received within the Warranty Period, at its 
option, Garner will either: (1) repair the product, (2) exchange the product, or (3) request that end-user replace defective parts 
with new or refurbished user-installable parts that Garner provides in fulfillment of its warranty obligations.  A replacement 
product or part, including a user-installable part that has been installed in accordance with instructions provided by Garner, 
assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever 
provides longer coverage.  Garner’s obligation is limited to the cost of material and labor to repair or replace and does not 
include transportation expenses.

 

 

LIMITATIONS 

This warranty does not apply:  (a) to cosmetic damage, including but not limited to scratches, dents and broken plastic; (b) to 
normal wear; (c) to damage caused by accident, abuse, neglect, misuse, flood, fire, earthquake or other external causes; (d) to 
damage caused by operating the product outside the permitted or intended uses described by Garner; (e) to damage caused by 
service performed by anyone who is not a representative of Garner or a Garner authorized service provider; (f) to a product or 
part that has been modified to alter functionality or capability without the written permission of Garner; or (g) if any Garner serial 
number has been removed or defaced. 
 

DISCLAIMER 

TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN 
LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, STATUTORY, 
EXPRESS OR IMPLIED. AS PERMITTED BY APPLICABLE LAW, GARNER SPECIFICALLY DISCLAIMS ANY AND ALL 
STATUTORY OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, 
FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS, IF GARNER 
CANNOT LAWFULLY DISCLAIM STATUTORY OR IMPLIED WARRANTIES, THEN TO THE EXTENT PERMITTED BY LAW.  
ALL SUCH WARRANTIES SHALL BE LIMITED IN DURATION TO THE DURATION OF THIS EXPRESS WARRANTY AND TO 
REPAIR OR REPLACEMENT SERVICE AS DETERMINED BY GARNER IN ITS SOLE DISCRETION.  No Garner dealer, 
reseller, agent, or employee is authorized to make any modification, extension, or addition to this warranty.  If any term is held to 
be illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or impaired. 

 

EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE EXTENT PERMITTED BY LAW, GARNER IS NOT 
RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH 
OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOSS OF 
USE; LOSS OF REVENUE; LOSS OF ACTUAL OR ANTICIPATED PROFITS (INCLUDING LOSS OF PROFITS ON 
CONTRACTS); LOSS OF USE OF MONEY; LOSS OF BUSINESS; LOSS OF OPPORTUNITY; LOSS OF GOODWILL; LOSS 
OF REPUTATION; LOSS OF DAMAGE TO OR CORRUPTION OF DATA; OR ANY INDIRECT OR CONSEQUENTIAL LOSS 
OR DAMAGE HOWSOEVER CAUSED INCLUDING THE REPLACEMENT OF EQUIPMENT AND PROPERTY, ANY COSTS 
OF RECOVERING, PROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED OR USED AND ANY 
FAILURE TO MAINTAIN THE CONFIDENTIALITY OF DATA.  IN NO EVENT SHALL GARNER BE LIABLE FOR ANY CLAIMS, 
WHETHER ARISING FROM BREACH OF CONTRACT OR WARRANTY OR CLAIMS OF NEGLIGENCE OR NEGLIGENT 
MANUFACTURE, IN EXCESS OF THE PURCHASE PRICE. 

 

WARRANTY RETURN POLICY 

 
If a problem occurs with this product, contact Garner directly by 

Email at [email protected]

 or by 

phone at (916) 

784-0200

 to obtain technical support and/or to get a Return Authorization Number (RA#).  All returns must be specifically 

authorized by Garner prior to shipment and returned to Garner 

FREIGHT

 

PREPAID 

with the RA# marked prominently near the 

shipping label.

  

Securely package the product

.  I

t is end-user’s responsibility to ensure the product is packaged properly to 

prevent damage during transit to Garner.

  

Garner will provide product packaging to end-user at end-user’s request and expense

.

  

Enclose proper documentation, including RA#, the return address, a name and phone number of the contact person, the serial 
number of the merchandise being returned and a description of the reason for the return.  Omission of any of this information 
may delay service.  Garner recommends end-user insure the shipment; otherwise end-user accepts the risk if product is lost or 
damaged in shipment.   
 
Garner will pay to ship the repaired or replacement products to end-user’s shipping dock if end-user’s delivery address is in the 
United States (excluding Puerto Rico and U.S. possessions and territories); otherwise Garner will ship the product to end-user 
freight collect.

  

Garner will select method for return shipment.  Alternate shipment methods may be made at end-user’s expense.   

 

 

Содержание HD-3WXL Series

Страница 1: ...stallation Manual HD 3WXL Series Continuous Degaussing System Operation and Installation Manual www Garner Products com 800 624 1903 10620 Industrial Ave Suite 100 Roseville CA 95678 Manufactured in the U S A PN 4075 244 Rev H ...

Страница 2: ...n 4 Power Plug 7 Fuse Block 7 Placement 7 Cooling 7 OPERATION 8 Controls and Indicators 8 POWER Button ON Indicator Yellow 8 LCD Display 8 Degaussing Instructions 8 Automatic Degaussing 8 Powering Up 8 Automatic Degaussing Steps 9 Automatic Degaussing Technical Detail 10 Degaussing Instructions for DLT Media 11 Error Codes 12 Charge Error 12 Door Open Error 12 Gauss Error 12 Overheat Error 12 Ejec...

Страница 3: ...HD 3WXL Operation and Installation Manual 1 DECLARATION OF CONFORMITY ...

Страница 4: ...oercivity media while also limiting the magnetic field exposure to 1 second for every 20 pieces of media degaussed Distance from side of degausser Magnetic field 0 0cm Duration of Field 61 gauss 0 05 Second 6 15cm 6 gauss 0 05 Second 12 30cm 2 gauss 0 05 Second Note The testing room measured 0 4 gauss before degausser was plugged in Average Operational Distance AOD from user to the HD 3WXL is 12 1...

Страница 5: ...harging 4 0A At the time of ERASE 0 3A Degausser System Capacitive Discharge Operating Time Duty Cycle Continuous Erasing time 10 milliseconds Cycle time 9 seconds per cycle Magnetic Field 10 000 Oe Peak 9 200 Oe measured in center Max Media Size 6 75 in 171mm W x 4 5 in 114mm H x 1 8 in 45 7mm D Erasing Area Size 6 75 in 171mm W x 4 5 in 114mm H x 1 8 in 45 7mm D Media 2 5 type HDD 3 5 type HDD D...

Страница 6: ... this manual INSPECTION POWER REQUIREMENTS INSTALLATION Check the power specifications label located on the back of the degausser It is important to ensure the correct power is applied to the degausser Call Garner Products Inc if the voltage listed is not compatible with your voltage International customers call 011 916 784 0200 Input Voltage Configuration The HD 3WXL model is equipped with a volt...

Страница 7: ...ollow the steps listed below 1 Read the Warning labels on the preceding page and on the HD 3WXL 2 Remove the power cord from the back of the HD 3WXL 3 Confirm and note the outlet voltage the HD 3WXL will plug into 4 Loosen the 4 screws from the Voltage Selection Panel and remove the Voltage Selection Panel ...

Страница 8: ... Panel confirm the correct jumper setting for the outlet voltage noted in Step 3 6 To change the jumper position pull the brown jumper wire from terminal on the upper side of the fuse block and move it to the corresponding terminal that matches your outlet voltage This photo shows the correct jumper setting for 120 VAC ...

Страница 9: ...he same voltage range can be used as spares Placement The degausser must be placed on a flat hard surface with a minimum 6 inch 15cm space from any object that may interfere with the cooling fan exhaust located on the backside of the degausser As a general rule media not intending to be erased should be kept at least 2 ft 60cm away from the degausser Cooling Forced air cooling is used to maintain ...

Страница 10: ...splay gives status automatic count total count software version field strength user instructions and fault messages DEGAUSSING INSTRUCTIONS The HD 3WXL media degausser operates automatically when media is inserted into the media door Automatic Degaussing Sensors built into the Media Entrance Door sense that a hard drive has been inserted The act of depositing media through the Media Entrance Door ...

Страница 11: ...splays Degausser Model FIRMWARE VER Displays current firmware version TOTAL Displays total erasing cycles Number on left indicates number of times the counter reached 50 000 Insert Media Session 0 Ready for media to be placed in the Media Entrance Door Counter for erase cycles from power up Step 3 Insert media Door Open Indicates Media Entrance Door is open this is normal when inserting media to b...

Страница 12: ...ld The portion of the graph represents the normal range for field strength level The I within the indicates where the erasing field strength measured The position of the I can vary from cycle to cycle as it is based on the actual field strength 6 If the field is in the normal range the LCD will display DATA ELIMINATED 7 If the field is not in the normal range the LCD will display ERASE FAILURE As ...

Страница 13: ...re Note For DLT media that is to be re used Although the data is completely degaussed in one operation a second pass rotated at 90 degrees is required to smooth out any magnetic fluctuation Note If the second pass is not completed the tape drive may eject the tape and indicate that the tape needs cleaning Performing a second pass of the DLT through the HD 3WXL at 90 degrees will correct this condi...

Страница 14: ...ror indicates the erasing field may not have been adequate to effectively erase the media in the degaussing chamber Media will not be ejected Action Turn off the HD 3WXL for approximately one minute Turning off the power to the HD 3WXL will clear the error Turn the HD3 WXL back on To initiate the degauss cycle with media already in the degaussing chamber push the Media Entrance Door open and let i...

Страница 15: ... 244F Manual operation HD 3WXL 4300 006 Fuse 15A 250V 4300 022 Fuse 7 5A 250V 4700 043 Surge Resistor 4800 009 SCR Module 4800 012 Zener Diode 160V 50W 4800 017 Blocking Diode 5100 035 Switch PB Ilum Red on mom 5100 037 Switch PB Ilum Yellow on off 5100 036 Switch PB Ilum Green on mom 5600 022 Transformer toroidal SA1400 219G Media Transport Assy HD 3WXL SA1400 221G Assy front panel chassis SA1400...

Страница 16: ... REPLACEMENT SERVICE AS DETERMINED BY GARNER IN ITS SOLE DISCRETION No Garner dealer reseller agent or employee is authorized to make any modification extension or addition to this warranty If any term is held to be illegal or unenforceable the legality or enforceability of the remaining terms shall not be affected or impaired EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE EXTENT PERMITTED BY LAW ...

Отзывы: