HD-3WXL Operation and Installation Manual
9
Automatic Degaussing Steps
Step 1:
Press POWER button ON.
Step 2:
Wait for the LCD to display “
Insert Media
”.
Step 3:
Insert media through the Media Entrance Door.
Step 4:
Remove degaussed media from Media Slide.
Step 5:
Repeat Steps 2,3 & 4.
The following information appears on the LCD Display from power-up through one automatic
degaussing cycle:
Action
LCD Display
Description
Step 1:
Press POWER
button ON
Step 2:
{Initial startup
sequence.}
GARNER
PRODUCTS, INC.
Displays Manufacturer.
HD-3WXL
DATA ELIMINATOR
Displays Degausser Model.
FIRMWARE VER
##
Displays current firmware version.
TOTAL
#
−−
##
Displays total erasing cycles.
Number on left indicates number of
times the counter reached 50,000.
Insert Media
Session = 0
Ready for media to be placed in
the Media Entrance Door.
Counter for erase cycles from
power up.
Step 3:
Insert media
Door Open
Indicates Media Entrance Door is
open – this is normal when
inserting media to be erased.
Erase Cycle
Initiated
Door has closed and the erase
cycle has started.
Charging
>>>>>>>>>>>>>>>>
Displays capacitor charging status.
--------------===|==
Visual indicator of erasing field
strength.
Data Eliminated
Indicates power and erasing field
strength was verified good and
data has been eliminated.
Media
Released
Media gate has lowered and
erased media will slide out.