Maintenance Manual
190-02472-02
G3X Touch EFIS Part 23 AML STC
Revision 2
Page 82
Figure 7-7 – Static Pressure Calibration
5. Select “OK” to continue the calibration.
Figure 7-8 – Static Pressure Calibration Warning
6. Ensure that all on-screen instructions have been complied with and all information displayed is
correct, then select the “Start” button to begin the calibration.
Figure 7-9 – Static Pressure Calibration Instructions
7. At each calibration point (sea level, 10K, 20K, and optionally 30K ft), the display will present a
screen that allows time to establish the calibration pressure before continuing.
Figure 7-10 – Static Pressure Calibration in Progress