Page 6-4
G1000 Nav III Line Maintenance Manual
Rev. L
190-00352-00
6.5
Category B Long Term Power Interrupt Annual Inspection Procedure
1.
Before beginning the Category B Long Term Power Interrupt Annual Inspection Procedure, the
test software “GDU Backup Cap Test Software (006-B0380-15)” must be downloaded from the
Garmin website:
a.
Access the Dealer Resource portion of the Garmin website (www.garmin.com).
b.
From the Technical Resource list, click on the “GDU Backup Cap Test Software
(006-B0380-15)” link.
c.
Extract the files onto a blank SD card.
2.
Remove the Supplemental Data Card from the lower slot of the GDU before loading any
software. Supplemental Data Cards left inserted can become corrupt, making them unusable.
Replacing corrupt cards is not covered under warranty
3.
Insert the SD card containing the test software into the top slot of the MFD.
NOTE
Loading “GDU Backup Cap Test Software (006-B0380-15)” to the GDUs
temporarily changes the GDU software version to v7.10. It is required to return
the system to the currently approved system software version and configuration
following the Long Term Power Interrupt Test.
4.
Power the MFD on in configuration mode by holding down the ENT key while applying power
(release the ENT key when the words “INITIALIZING SYSTEM” appear on the display).
5.
Press the ENT key at the “DO YOU WANT TO UPDATE SYSTEM FILES?” prompt.
6.
Press the ENT key to confirm software update completion.
7.
Remove the SD card from the MFD and insert into the top slot of the PFD (leave the MFD on in
configuration mode).
8.
Power the PFD on in configuration mode by holding down the ENT key while applying power
(release the ENT key when the words “INITIALIZING SYSTEM” appear on the display).
9.
Press the ENT key at the “DO YOU WANT TO UPDATE SYSTEM FILES?” prompt.
10.
Press the ENT key to confirm software update completion.
11.
Use the FMS knob to select the SYSTEM UPLOAD Page.
12.
Select the configuration file “Backup Capacitor Test 50ms” from the SYSTEM UPLOAD Page
(Figure 6-1).
Figure 6-1. Backup Capacitor Test Selection
13.
Press the ENT key to confirm the configuration file selection.
14.
Press the LOAD softkey to load the configuration file.
Содержание G1000 NAV III
Страница 1: ...190 00352 00 March 2008 Rev L G1000 NAV III LINE MAINTENANCE MANUAL ...
Страница 28: ...Page 1 18 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Страница 120: ...Page 2 92 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Страница 178: ...Page 5 4 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 This page intentionally left blank ...
Страница 184: ...Page 6 6 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...
Страница 248: ...Page B 34 G1000 Nav III Line Maintenance Manual Rev L 190 00352 00 Blank Page ...