Part #: GAR_IOM_ 4532522 Rev 08—6/17
35
Section 2
Installation
d. turn off the grill, remove the manometer and re-
fit the sealing screw on the pressure spigot and
regulator.
e. test those connection for leaks.
f. these procedure must be done by qualify technician
only.
•
Gas pressures should be checked by the local Gas
Company or an authorized service agency only.
•
Test all piping and connections for gas leaks. A rich soap
solution should be used for this purpose. Never use a
flame. If inside unit, protect electronic components/
boards before leak testing with soap solution.
•
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
greater than ½ psi (3.5 kPa).
•
If included, Install the quick-disconnect gas hose to
the inlet fitting on the underside of the grill. Remove
the dust cap from the male coupler and snap the
quick disconnect fitting on the gas hose assembly
onto the male coupler.
MALE COUPLER
ALREADY INSTALLED
TO GAS
SUPPLY
FACTORY
INSTALLED
GAS INLET
UNDERNEATH GRILL QUICK-DISCONNECT
FLEXIBLE GAS HOSE
GAS
FLOW
•
Ensure the sleeve snaps fully forward against the
retaining ring.
•
With the manual shut-off valve closed, and gas hose
assembly disconnected from the unit install the
other end of the hose to the gas supply.
•
Affix Shut-Off sticker as shown below:
Electrical Connection
Warning
Disconnect power supply before starting this procedure.
•
All electrically operated appliances must be electrically
grounded in accordance with local codes; or in the
absence of local codes, with the latest edition of
National Wiring Regulations. A wiring diagram is located
on the rear panel of the grill. See rating serial plate
mounted on the lower left corner of the right panel for
proper voltages.
•
The entry point for the electrical connection is located
on the bottom of the appliance.
•
Do not
cut or remove the grounding prong from the
plug.
•
Adequate means of disconnection of the supply must
be provided.
•
It is recommended to allow enough slack on the
electrical cord to allow the appliance to be pulled out
for proper cleaning and maintenance.