Section 1
Gas Input Specification
Determining Unit Configuration for Gas Grills:
a.
If the grill has been supplied with the following label (Figure label #1), it has been configured for standard elevation
which is 0 - 4,500 feet (0 - 1372 m).
STANDARD GAS SETTINGS/SPECIFICATIONS FOR CSA APPROVED MODELS
GAS TYPE
STANDARD
ELEVATION
FAN
SPEED
PRESSURE SWITCH
SETTING
INPUT/
BURNER
"TOTAL INPUT/UNIT
BTU"
SUPPLY
PRESSURE
MANIFOLD
PRESSURE
INJECTOR
SIZE
FEET
RPM
" W.C.
CLOSE /
OPEN
Colour
Code
BTU
12in
GRILL
24in
GRILL
36in
GRILL
" W.C.
" W.C.
mm
Natural Gas
CSA
0
- 4500
10,000
0.15 /
0.07
Grey
10,000
20,000 40,000 60,000
7.0
4.0
1.5
Propane Gas
CSA
0
- 4500
10,000
0.15 /
0.07
Grey
10,000
20,000 40,000 60,000
11.0
4.0
1.2
STANDARD GAS SETTINGS/SPECIFICATIONS FOR CE APPROVED MODELS
GAS TYPE
ELEVATION
RANGE
FAN SPEED
PRESSURE SWITCH
SETTING
INPUT/
BURNER
"TOTAL INPUT/UNIT
kW"
SUPPLY
PRESSURE
MANIFOLD
PRESSURE
INJECTOR
SIZE
METERS
RPM
" W.C.
CLOSE /
OPEN
Colour
Code
kW
12in
GRILL
24in
GRILL
36in
GRILL
mbar
mbar
mm
Natural Gas
G20
0
- 1372
10,000
0.32 /
0.24
Red
2.93
5.86
11.72
17.58
20.0
10.0
1.5
Natural Gas
G25
0
- 1372
10,000
0.32 /
0.24
Red
2.93
5.86
11.72
17.58
25.0
13.7
1.5
Propane Gas
G31
0
- 1372
10,000
0.32 /
0.24
Red
2.93
5.86
11.72
17.58
" 30.0
*37.0
50.0"
10.0
1.2
*The regulator on each gas valve has been adjusted at the factory for a 37mbar supply pressure. An authorized installer may need to
adjust the regulator setting to maintain the correct manifold pressure for 30mbar and 50mbar installations.
For installations up to 4500 ft (1372 meters). Units being installed at higher elevations must be configured accordingly at
the factory or modified at the installation site by a factory authorized technician, using the appropriate certified conversion
kit listed in this manual.
Figure label #1