INSTALLATION INSTRUCTIONS Continued

 

NOTE:

  When using thread compound, use very small 

amounts on male threads only.  Use a pipe thread 

compound that is not affected by the chemical action of 

LP gases (i.e. propane, G31) (Loctite™ PST56765 Sealant is 

one such compound).  DO NOT apply compound to the 

first two threads.  This will ensure that the burner orifices 

and control valve do not become clogged.  

2.  Open the gas supply to the cooker and check all piping, 

fittings, and gas connections for leaks.  A soap solution 

should be used for this purpose.

 DANGER

Never use matches, candles, or any other ignition source 

to check for leaks.  If gas odors are detected, shut off the 

gas supply to the cooker at the main shut-off valve and 

contact the local gas company or an authorized service 

agency for service.

3.  Close the cooker drain valve and fill the cookpot with 

water and detergent.  Light the cooker and perform the 

boil-out procedures that are described in the “Boiling Out 

the Cookpot” section.

n

WARNING

“Dry-firing” this equipment will cause damage to the 

cookpot.  Always ensure that water is in the cookpot 

before firing your unit.

4.  It is recommended that the burner gas pressure be 

checked at this time by the local gas company or an 

authorized service agent.  Refer to “Adjusting the Burner 

Gas Pressure” section of this manual for the proper 

procedure.  The accompanying tables list the burner gas 

pressures for the various gas types that can be used with 

this equipment.

Standard for Incoming Gas Pressures

Gas

Pressure

Natural

3” WC

.87 kPa

8.718 mbar

Propane

8.25” WC

2.054 kPa

20.55 mbar

Converting to Another Gas Type

 DANGER

Your cooker is configured at the factory for a specific 

type of gas.  If you desire to switch from one type of gas 

to another, specific gas-conversion components must be 

installed.
Switching to a different type of gas without installing 

the proper conversion components may result in fire or 

explosion!  NEVER attach your cooker to a gas supply for 

which it is not configured.
Conversion of this appliance from one type of gas to 

another should only be performed by qualified, licensed, 

and/or authorized installation or service personnel, as 

defined in section - Installation, Operating and Service 

Personnel.

Gas Conversion Components

Natural Gas to LP (Propane) 

Gas:

LP (Propane) Gas to Natural 

Gas:

Orifice

:  810-0386 (2 

required)

Ignitor Kit

:  826-0982 (2 

required)

Regulator

:  807-1848 (1 

required)

Conversion Rating Label 
802-2144

.

Orifice

:  810-0403 (2 required)

Ignitor Kit

:  826-0981 (2 required)

Regulator

:  807-1847 (1 required)

Conversion Rating Label 802-
2144 .

Gas Conversion Instructions

1.  Change the orifices.

2.  Change the ignitors.

3.  Install the regulator kit in the gas valve in accordance 

with the instructions furnished with the kit.

4.  Adjust the incoming gas pressure for the new gas.  (Refer to 

the 

Standard for Incoming Gas Pressures

 table on this page.)

5.  Adjust the gas pressure at the gas valve regulator.  (Refer 

to the 

Standard for Burner Gas Pressures

 table on this page 

and section - Adjusting the Burner Gas Pressure. )

6.  Affix the new label included with the conversion kit 

next to the existing rating plate stating that the gas 

type has been converted.  Remove any references to the 

previously used gas from the existing rating plate.  Label 

PN  802-2144.

7.  If the destination language changes, replace the labels.  

(You must contact your local service agency. The 

language of reference is indicated on the corner of the 

label.)

Содержание PASTA MAGIC

Страница 1: ...nd web site at http www garland group com The information contained herein including design and parts specifications may be superseded and is subject to change without notice WARNING IMPROPER INSTALLA...

Страница 2: ...BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL INC BOCA AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION GARLAND PASTA COOKERS EQUIPPED WITH LEGS ARE FOR PERMANENT...

Страница 3: ...eparations 7 Connection to Gas Line 8 Converting to Another Gas Type 9 Operating Instructions 10 Finding Your Way Around the Pasta Cooker 10 Controller 11 Operating Instructions 12 Start up Procedure...

Страница 4: ...n addition to the model number serial number and type of gas please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your...

Страница 5: ...gas fired appliances Qualified personnel must be experienced in such work be familiar with all gas precautions involved and have complied with all requirements of applicable national and local codes...

Страница 6: ...s defined in Section 1 5 of this manual should perform all installation and service on Garland equipment Conversion of this appliance from one type of gas to another should only be performed by qualif...

Страница 7: ...cooker door Connect a cooker only to the type of gas indicated on the rating plate Installation shall be made with a gas connector that complies with the national and local codes or regulations in fo...

Страница 8: ...egulatory agency of the country in which the appliance is installed 4 For units equipped with basket lifts install the basket lift arms onto the rods located at the top rear of the cabinet to ensure t...

Страница 9: ...ng to Another GasType DANGER Your cooker is configured at the factory for a specific type of gas If you desire to switch from one type of gas to another specific gas conversion components must be inst...

Страница 10: ..._PASTACUISINE_4607873 08 21 10 OPERATING INSTRUCTIONS FindingYourWay Around the Pasta Cooker Overflow Low water sensor High water sensor Temp probe Drain Cook pot Trouble light Controller Drain valve...

Страница 11: ...ces the efficiency of the cooker and can cause erroneous temperature and water level sensing NOTE Do not use deliming solution to clean these units Use of deliming solution will damage all stainless s...

Страница 12: ...hould display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires adjustment as explained below NOTE Adjusting the Air Gas Mix...

Страница 13: ...r turn the unit off and add cold water until the solution is cool Drain the solution and clean the cookpot thoroughly with a solution of dishwashing detergent and hot water 5 Rinse the cookpot at leas...

Страница 14: ...water and or food products Clean Water Level Sensors Temperature Probe Cookpot and Rinse Tank 1 Turn the equipment off and drain the cookpot and rinse tank if so equipped 2 Remove the probe cover and...

Страница 15: ...display a bright orange red glow If a blue flame is observed or if there are dark spots on a burner face the air gas mixture requires ad justment On the side of the blower housing opposite the motor...

Страница 16: ...sing wire was removed 3 Place the power switch in the ON position to light the burners After the cookpot temperature reaches 2000F 930C wait at least one minute before checking the reading NOTE The cl...

Страница 17: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 18: ...the Welbilt KitchenCare HOTLINE 844 724 2273 Verify that electrical cords are plugged in and that circuit breakers are on Verify that water supply valves are open and that the drain valves are fully c...

Страница 19: ...es not sense sufficient water in the cookpot it will not allow the burners to fire B Remove the probe block cover and clean the sensors using a Scotchbrite or similar pad and a solution of detergent a...

Страница 20: ...oller If the AUTOFILL functions correctly the only cause possible is a failed controller A Order replacement controller from FASC or distributor WATER WILL NOT BOIL Cookpot verified to be full of wate...

Страница 21: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 21 Notes...

Страница 22: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 22 Notes...

Страница 23: ...Document G_GHD_OM_PASTACUISINE_4607873 08 21 23 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 24: ...therm Crem Delfield fitkitchen Frymaster Garland Kolpak Lincoln Manitowoc Merco Merrychef and Multiplex Bringing innovation to the table welbilt com 2021 Welbilt Inc except where explicitly stated oth...

Отзывы: