INPUT SPECIFICATIONS
(continued)
SUPPLY
TOTAL
kW
LOAD
NOMINAL AMPS PER LINE
208V / 60Hz
220V / 60Hz
240V / 60Hz
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
5.6kW
15.6
15.6
15.5
14.7
14.7
14.7
13.5
13.5
13.5
GAS INPUT
GAS
MAX INPUT
(NET) PER
BURNER
(BTU/H)
TOTAL INPUT
RATING
(BTU/H)
INJECTOR
SIZE
AIR SHUTTER
SETTING
(*)
SUPPLY
PRESSURE
(IN W.C.)
BURNER
MANIFOLD
PRESSURE
(IN W.C.)
NATURAL GAS
32,000
32,000
#35
50%
7.0
3.5
PROPANE
32,000
32,000
1.75mm
50%
11.0
10.0
Input Specifi cations, GAS SINGLE PLATEN MWG1W Grills, North America:
TOTAL
kW
LOAD
LOADING: (kW/PHASE)
NOMINAL AMPS PER LINE
380V / 400V / 415V
380V
400V
4150V
L1/N
L2/N
L3/N
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
5.7kW
1.8
1.8
1.9
8.5
8.5
8.9
8.1
8.1
8.5
7.8
7.8
8.2
GAS INPUT
GAS GROUP
MAX INPUT
(NET) PER
BURNER (kW)
TOTAL INPUT
RATING (kW)
INJECTOR
SIZE
AIR SHUTTER
SETTING (mm)
(*)
SUPPLY
PRESSURE
(mbar)
BURNER
PRESSURE
(mbar)
VOLUMETRIC
GAS RATE
G20 NG
8.6
8.6
2.64mm
9.0
20/25
8.7
0.91m
3
/h
G31 LPG
8.6
8.6
1.61mm
9.0
37/50
24.9
0.67kg/h
GAS CATEGORIES
CATEGORY
DESTINATION COUNTRIES
SUPPLY PRESSURE (mbar)
I
2H
AT, CH, CZ, DK, ES, FI, GB, IE, IS, IT, NO, PT, SE
20
I
2E
DE, LU
20
I
3P
NL
30
I
3P
BE, CH, CZ, ES, FR, GB, GR, IE, LU
37
I
3P
BE, CH, DE, CZ, ES, FR, NL
50
(*) NOTE: Air shutter setting may vary by region. Only a qualify service technician should make adjustments
for proper combustion
Input Specifi cations, GAS SINGLE PLATEN MWG1W Grills, CE Approved Model: