INSTALLATION/OPERATION & SERVICE MANUAL - 1&2 PLATEN
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
PART #4527466 (12 Aug 2011)
Page 48
SOFTWARE V222
System Menu
Sub Menu
Options
Description of Options
Default
Configure Menu
Electric
Gas
Yes
No
World
Japan
Time Then Alarm
Japan Fixed 10S
Left
Center
Right
Yes
No
On
Off
Auto Standby Delay
1-5
Seconds in which alarm will sound when alerting operator to put grill in standby.
3
Setup
Temperature Units
F (Fahrenheit)
C (Celcius)
Time Unit
sss
mss
mmm
Key Chirp
Yes
No
Audible
3 Second
Strobe
Song
Audio Volume
1-100 (Adjustable)
Alarm volume
100
Reload Defaults
Yes
No
Multi Gap
Yes
No
Audible Select
0
1
2
Auto Mode Enable
Yes
No
Product Rec Timeout
0-30
Maximum number of seconds to recognize product. If product is not recognized in [Product Rec Timout} time, then "Product Not
Rec"
10
Heater Err Timer
60-1200
Number of seconds the controller must see a temperature rise before "Heater Error"
425
Too Cool Lo Lmt
OFF, 1F/C-450F / 250C
110F / 61C
Calibration
Level / Reed Switch
Yes
No
Auto Gap Force
Yes
No
Probe Cal
All Temperature Zones
Mode to perform a temperature probe calibration
Gap Calibration
-1000 - 1000
Gap Offset - Offsets Gap setting for all menu items.
0
Reed Switch Min
0 - 1000
Maximum Δ CAL before warning / error msg
200
Reed Switch Max
0 - 1000
Maximum Δ CAL before disabling clam operation.
300
Delta Speed Err
0-20
Number corresponds to linear actuator motor speed.
Adjusts automatically.
Pivot End Mills
800 - 3000
Number set corresponds to location of pivot block to determine pivot point and decreased motor speed.
1100
Show Reed Data
YES/NO
When activated to YES, controller will display encoder counts when reed switches close.
No
Front Reed Cal
XXX
During Auto Calibration, the encoder counts when Front Reed Switch Closed.
Back Reed Cal
XXX
During Auto Calibration, the encoder counts when Back Reed Switch Closed.
F ZERO Cal
XXX
During Auto Calibration, the encoder counts when Front Reed Switch Opened.
B ZERO Cal
XXX
During Auto Calibration, the encoder counts when Back Reed Switch Opened.
F ARM OFFSET_MIN
-3000 - 1000
Calculated Offset of arm deflection.
-20
Cal Delta Percent
XXX
Factor of error calculated in control.
25%
Diagnostic
Date Code
YYDDD
Date-of manufacturer
Serial Number
XXXXXX
Serial No.
Part Number
N3AF-XXX-XXX
Control Part Number
N2AF-0307-CNTL
App VERSION
XX.XX.XXX
Software Revision Number
04.01.202
CLM 1 Version
XX.XX.XXX
Control Loop Module Revision 1
01.00.046
CLM 2 Version
XX.XX.XXX
Control Loop Module Revision 2
01.00.046
Audio Version
XX.XX.XXX
Audio Code Revision
01.00.018
Motor Version
XX.XX.XXX
Motor Control Revision Number
06.00.034
Ambient 1
XXXX F/C
Actual Internal Temperature Ambient
Ambien 2
XXXX F/C
Actual Internal Temperature Ambient (With Offset)
Ambient 3
XXXX F/C
Actual Internal Temperature Ambient (With Offset)
Top Probe
XXXX F/C
Actual Temperature Top Probe
Grill Probe F
XXXX F/C
Actual Temperature Front Probe
Grill Probe M
XXXX F/C
Actual Temperature Middle Probe
Grill Probe B
XXXX F/C
Actual Temperature Back Probe
External probe
XXXX F/C
Actual Temperature External Probe
OFF
PR Front Detect
XXX
Last PR Value Detected By Front Reed Switch
PR Back Detect
XXX
Last PR Value Detected By Backt Reed Switch
PR Table Value
XXX
Last PR Table Value Calculated
Service
Encoder Counts
87-3500
Encoder Counts Brom Bottom Limit Sw Top Limit Sw
Motor Status
xxx
Motor status Code - Operating Parameter
15
Switch Status
xxx
Switch Status Code - Operating Parameter
Startup Rate
x
Startup Rate Code - Operating Parameter
8
Buss Voltage
198 +/- 10%
Controller Buss Voltage
Motor Max Speed
64
Motor Max Speed Code
64
Motor Revision
xxx
Motor Revision
152
Motor Error
x
Motor Error Code - Operating Parameter
0
Lonworks Service
Yes / No
Lonworks Activated
NO
Mode where user can perform an Auto Calibration upon request.
No
1
Yes
Mode where technician performs Platen Leveling procedure, and Reed Switch Calibration procedure
No
Pitch of tone in controller
Enables or disables product recognition cooking in control.
Yes
Yes
OFF
F
sss
Enabled Multi Gap cooking on or off.
Setting to display temperature units in Fahrenheit or Celcius.
Setting to display time Units:
sss - Seconds
mss - Minutes / Seconds (M:SS)
Setting that turns the sound on/off when a button is pressed.
Audible sound when remove alarm is sounding.
Electric
Yes
World
Left
When Yes is selected, the control will automatically begin to reload its factory defaults. In this setting, only menu item defaults are
reloaded.
Yes
3 second
No
Grill Region
Cook Zone
Setting to determine regional setup requirements.
Placement of control on grill.
Setting that tells control whether grill is electric or gas. Must be set correctly to identify number of heat zones.
Setting in control that tells whether platen is present. I.E: Flat grills (No Platens).
Grill Type
Platen Enabled
Time Then
Current requirements are for 2 stages of gap. This setting when set to Yes shows all 3 additional multi gap settings.
Turns on/off the automatic alarm to alert the operator to put grill in standby.
More Multi Gap
Auto Standby Timer
Remove Alarm
FUNCTION OPTIONS; SYSTEM MENUS