![Garland MASTER SERIES XG24CE GB/IE Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/garland/master-series-xg24ce-gb-ie/master-series-xg24ce-gb-ie_installation-and-operation-manual_564373008.webp)
Part # 4517127 (06/23/08)
Page 8
INSTALLATION continued
• Screw the lock nut on each castor tight against the
bottom of the unit.
• When the unit is in place, lock the front castors to prevent
movement.
Grill plate must be level front to back, side to side and
diagonally. This leveling must be done with the unit under
the hood and in it’s normal operational position to prevent
warping of the grill plate.
Electrical Connections:
Electrical connections must be in accordance with the
current IEE Wiring Regulations. The supply should have a
contact separation of at least 3mm on all poles. Adequate
means of disconnection of the supply must be provided.
It is recommended that this grill be connected to a residual
current (earth leakage) device with a tripping current not
exceeding 30mA. The leakage current of this grill will not
exceed 5mA.
CAUTION:
Prior to installation, check the electrical supply
to ensure input voltage and phase match the equipment
voltage rating and phase. See data plate located rear left side
of grill and lower front panel.
The entry point for the electrical connection is located on
the base of the appliance. Remove the punch-out plate, and
punch out the required size to the supply cable. Secure the
cable in place with a gland fitting and suitable means of
strain relief.
All electrically operated appliances must be electrically
earthed in accordance with local codes; or in the absence
of local codes, with the latest edition of National Wiring
Regulations. A wiring diagram is located on the rear panel of
the grill. See rating plate in rear of grill, or lower front panel
for proper voltages.
Burner Manifold Pressure Test/Adjustment:
Burner operating gas pressure can be checked at the outlet
side of the gas valve at the pressure test point.
To adjust the burner pressure:
1. The pressure test nipple is located in the gas valve on the
side opposite the burner.
2. Remove the sealing screw from the pressure test nipple
and connect a manometer.
3. Remove the sealing cap on the gas valve regulator, turn
on the grill, and adjust the screw in the regulator to give
the correct pressure.
4. Turn off the grill, refit the regulator sealing cap, remove
the manometer, replace the seal screw in the test nipple
and test for gas leaks.
Gas pressures should be checked by the local Gas Company
or an authorized service agency only.
Test all piping and connections for gas leaks. A rich soap
solution should be used for this purpose. Never use a flame.
Burner Ignition Verification by the Installer:
Once the grill is properly installed, turn the grill power switch
on. Press the ON/OFF switch on the grill control to heat the
grill in Standby Mode. The will attempt to ignite the burners.
Verify Burner Ignition as Follows:
1. The controls will attempt to ignite the burners when the
grill calls for heat to the griddle plate.
2. If ignition does not occur on the first attempt, the lower
LED (for the grill plate) will begin to flash to alert the
installer that the first attempt at burner ignition has
failed.
3. The control will then attempt to ignite the burners up to
four (4) more times.
4. If, after four (4) attempts, the burners have not ignited,
the control will shut down and display “IGNITION ERROR.”
5. Inspect the gas and ignition systems for possible
problems.
Additional Burner Ignition Verification:
1. Drop the front control panel so that the heat shield is
visible.
2. Turn the grill ON and press the ON/OFF switch on the
control to heat the grill in Standby Mode.
3. Rotate the round shutter to expose the burner sight glass.
4. When the grill attempts to ignite the burners, look
through the sight glass to verify ignition.
The burner should ignite and the flame should appear blue
with no orange tipping. If the burner flame cannot be seen,
inspect ignition and gas system for possible problems.