Part # 4517127 (06/23/08)
Page 21
PROGRAMMING continued
6. Press to change the Gap Setting Display units to either
Inches or Millimeters.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”.
9. Press again to exit.
To Change the Alarm Volume:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press three, (3), times. “ALARM VOLUME LOW (or
HIGH)” will be displayed.
6. Use or to change the Alarm Volume to either Low
or High.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”.
9. Press again to exit.
To Change Probe Calibration - Upper:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press four, (4), times. “PROBE CAL – UPPER XXXF” will
be displayed.
6. Use or to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”
9. Press again to exit.
To Change Probe Calibration - Grill:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press two, (2) times. “PROGRAMMING MODE SYSTEM
SETUP” is displayed.
5. Press five, (5), times. “PROBE CAL – GRILL XXXF” will be
displayed.
6. Use or to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SYSTEM
SETUP”
9. Press again to exit.
*CALIBRATION REQUIREMENTS
The control software will beep to the user when it is
appropriate to calibrate. The control will allow calibration
provided the following conditions are met:
• Temperature is currently falling from a detected peak
of 360°F or higher.
• Temperature is falling and has fallen 2°F from a
detected peak that is within the 350-360°F range. (i.e.
calibration would be allowed at 355°F if the achieved
peak temperature was 357°F)
• Temperature is rising through the 350-360°F range as a
result of a heat on pulse of less than 30 seconds.