Part # 4517127 (06/23/08)
Page 24
Service Mode
To Change SCK Address:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press three, (3) times. “PROGRAMMING MODE SERVICE
MODE” is displayed.
5. Press one, (1), time. “Address XX” will be displayed.
6. Use and to change to the desired SCK Address.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE SERVICE
MODE”
9. Press again to exit.
To Perform Limit Switch Test:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press three, (3) times. “PROGRAMMING MODE SERVICE
MODE” is displayed.
PROGRAMMING continued
5. Press two, (2), times. “PLATEN” (along with the position
of each switch), will be displayed.
6. Use and to move the platen up and down. Check
for correct switch operation:
Correct Switch Operation:
Platen Up -
U (Closed) L (Open)
Platen Down -
U (Open) L (Closed)
7. Press to return to “PROGRAMMING MODE SERVICE
MODE”
8. Press again to exit.
Gap Button
To Change Gap Setting:
1. Press and hold for three, (3) seconds. “ENTER CODE”
will be displayed.
2. Using the Gap Setting buttons,
enter the
code, (1251). “ENTER CODE **** ” will be displayed.
3. Press to enter the Programming Mode.
“PROGRAMMING MODE MENU ITEMS” will be displayed.
4. Press . “GAP LEVEL 1 X.XXX” will be displayed.
5. Press until the desired Gap Level is displayed.
6. Use and to adjust the Gap Level to the desired
value.
7. Press to save the changes.
8. Press to return to “PROGRAMMING MODE MENU
ITEMS”
9. Press again to exit.